English
Language : 

030031AS Datasheet, PDF (8/9 Pages) Vishay Siliconix – Aluminum Capacitors Axial Standard
www.vishay.com
Table 5
TEST PROCEDURES AND REQUIREMENTS
TEST
NAME OF TEST
REFERENCE
PROCEDURE
(quick reference)
Case Ø D x L = 4.5 mm x 10 mm to 10 mm x 25 mm
Endurance
IEC 384-4/
EN130 300
subclause 4.13
Tamb = 85 °C; UR applied;
2000 h
Useful life
CECC 30301
subclause 1.8.1
Tamb = 85 °C; UR and IR applied;
3000 h
Shelf life
(storage at
high temperature)
IEC 384-4/
EN130300
subclause 4.17
Tamb = 85 °C; no voltage applied;
500 h
After test: UR to be applied for 30 min,
24 h to 48 h before measurement
030/031 AS
Vishay BCcomponents
REQUIREMENTS
UR  6.3 V; C/C: + 15 %/- 30 %
UR > 6.3 V; C/C: ± 15 %
tan   1.3 x spec. limit
Z  2 x spec. limit
IL  spec. limit
UR  6.3 V; C/C: + 45 %/- 50 %
UR > 6.3 V; C/C: ± 45 %
tan   3 x spec. limit
Z  3 x spec. limit
IL  spec. limit
no short or open circuit
total failure percentage:  1 %
C/C, tan , Z:
for requirements
see “Endurance test” above
IL  2 x spec. limit
Revision: 13-Apr-12