English
Language : 

CMA0204 Datasheet, PDF (7/8 Pages) Vishay Siliconix – High Pulse Load MELF Resistor
CMA 0204
Vishay Beyschlag
High Pulse Load MELF Resistor
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
following specifications:
EN 60115-1, generic specification
EN 140400, sectional specification
EN 140401-803, detail specification
The Test Procedures and Requirements table contains the
applicable tests selected from the documents listed above.
The tests are carried out in accordance with IEC 60068 and
under standard atmospheric conditions in accordance with
IEC 60068-1, 5.3. Climatic category LCT/UCT/56 (rated
temperature range: Lower Category Temperature, Upper
Category Temperature; damp heat, long term, 56 days) is
valid.
Unless otherwise specified the following values apply:
Temperature: 15 ˚C to 35 ˚C
Relative humidity: 45 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
The components are mounted for testing on printed-circuit
boards in accordance with EN 140400, 2.3.3, unless
otherwise specified.
The requirements stated in the Test Procedures and
Requirements table are based on the required tests and
permitted limits of EN 140401-803.
TEST PROCEDURES AND REQUIREMENTS
EN
60 115-1
CLAUSE
IEC 60068-2
TEST
METHOD
TEST
PROCEDURE
stability for product types:
CMA 0204
4.5
−
resistance
-
REQUIREMENTS
PERMISSIBLE CHANGE (∆R/R)
10 Ω to 100 kΩ
±2%
4.8.4.2 -
temperature coefficient
at 20 / − 55 / 20 ˚C
and 20 / 125 / 20 ˚C
see Temperature Coefficient graph
4.25.1 -
4.25.1 -
4.25.3
4.24
4.23
4.23.2
4.23.3
4.23.4
4.23.5
4.23.6
-
78 (Cab)
2 (Ba)
30 (Db)
1 (Aa)
13 (M)
30 (Db)
-
1 (Aa)
4.19
14 (Na)
endurance at 70 °C:
standard operation mode
endurance at 70 °C:
power operation mode
endurance at upper category
temperature
damp heat, steady state
climatic sequence:
dry heat
damp heat, cyclic
cold
low air pressure
damp heat, cyclic
cold
rapid change of temperature
U = P 70 × R ≤ Umax;
1.5 h on; 0.5 h off;
70 °C; 1000 h
70 °C; 8000 h
U = P 70 × R ≤ Umax;
1.5 h on; 0.5 h off;
70 °C; 1000 h
70 °C; 8000 h
125 °C; 1000 h
155 °C; 1000 h
(40 ± 2) °C; 56 days; (93 ± 3) % RH
UCT; 16 h
55 °C; 24 h; ≥ 90 % RH; 1 cycle
LCT; 2 h
8.5 kPa; 2 h; (25 ± 10) °C
55 °C; 24 h; ≥ 90 % RH; 5 cycles
LCT = − 55 °C; UCT = 155 ˚C
− 55 °C; 2 h
30 minutes at − 55 ˚C;
30 minutes at + 125 ˚C; 5 cycles
± (1 % + 0.05 Ω)
± (2 % + 0.05 Ω)
± (2 % + 0.05 Ω)
± (4 % + 0.05 Ω)
± (2 % + 0.05 Ω)
± (4 % + 0.05 Ω)
± (1 % + 0.1 Ω)
± (1 % + 0.1 Ω) no visible damage
± (0.5 % + 0.1 Ω)
± (0.5 % + 0.1 Ω)
www.vishay.com
7
For technical questions contact: ff3bresistors@vishay.com
Document Number: 28717
Revision: 27-Feb-04