English
Language : 

DG3408 Datasheet, PDF (6/14 Pages) Vishay Siliconix – Precision 8-Ch/Dual 4-Ch Low Voltage Analog Multiplexers
DG3408/3409
Vishay Siliconix
SPECIFICATIONS (SINGLE SUPPLY 3 V)
Parameter
Analog Switch
Analog Signal Rangee
On-Resistance
rON Match Between Channelsg
On-Resistance Flatnessi
Switch Off Leakage Currenta
Symbol
VANALOG
rON
ΔrON
rON
Flatness
IS(off)
ID(off)
Channel On Leakage Currenta
Digital Control
Logic High Input Voltage
Logic Low Input Voltage
Input Currenta
Dynamic Characteristics
ID(on)
VINH
VINL
IIN
Transition Time
tTRANS
Break-Before-Make Time
Enable Turn-On Time
Enable Turn-Off Time
Charge Injectione
Off Isolatione, h
Crosstalke
Source Off Capacitancee
tBBM
tON(EN)
tOFF(EN)
Q
OIRR
XTALK
CS(off)
Test Conditions
Unless Otherwise Specified
V+ = 3 V, ± 10 %, V- = 0 V
VEN = 0.4 V or 1.8 Vf
Tempb
V+ = 2.7 V, VD = 0.5 or 2.2 V, IS = 5 mA
V+ = ± 2.7 V, VD = 0.5 V or 2.2 V, IS = 5 mA
V+ = 3.3 V
VS = 2 or 1 V, VD = 1 or 2 V
V+ = 3.3 V
VD = VS = 1 or 2 V, Sequence Each Switch On
Full
Room
Full
Room
Room
Room
Full
Room
Full
Room
Full
Full
Full
VAX = VEN = 1.8 V or 0.4 V
Full
VS1 = 1.5 V, VS8 = 0 V, (DG3408)
VS1b = 1.5 V, VS4b = 0 V, (DG3409)
See Figure 2
VS(all) = VDA = 1.5 V
See Figure 4
VAX = 0 V, VS1 = 1.5 V (DG3408)
VAX = 0 V, VS1b = 1.5 V (DG3409)
See Figure 3
CL = 1 nF, RGEN = 0, VGEN = 0 V
f = 100 kHz, RL = 1 kΩ
f = 1 MHz, VS = 0 V, VEN = 1.8 V
DG3408
DG3409
Room
Full
Room
Full
Room
Full
Room
Full
Room
Room
Room
Room
Room
Limits
- 40 to 85 °C
Minc Typd Maxc
0
3
12
25.5
26.5
3.6
13
-2
2
- 20
20
-2
2
- 20
20
-2
2
- 20
20
1.8
0.4
-1
1
140 165
182
2
63
140 162
178
76
97
104
7
- 81
- 85
23
25
Unit
V
Ω
nA
V
µA
ns
pC
dB
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN = 1.8 V
DG3408 Room
DG3409 Room
230
120
pF
DG3408 Room
256
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 0 V
DG3409 Room
147
Power Supplies
Power Supply Current
I+
VEN = VA = 0 V or V+
Room
1.0
µA
Notes:
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
g. ΔrDON = rDON Max - rDON Min.
h. Worst case isolation occurs on Channel 4 due to proximity to the drain pin.
i. rDON flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
6
Document Number: 72858
S-70853-Rev. D, 30-Apr-07