English
Language : 

AC-AT Datasheet, PDF (6/12 Pages) Vishay Siliconix – Cemented Leaded Wirewound Resistors
www.vishay.com
AC, AC-AT
Vishay Draloric
PULSE DIAGRAMS
Pulse energy in joules or wattseconds is calculated with the help of the R-value to be used in the application. Choose the R
value on X axis and look for the corresponding E (Ws/) value on Y axis. Multiplying both the R () to corresponding E (Ws/),
will be resultant total pulse Energy (Ws or J) for adiabatic conditions.
100
10
1
0.1
0.01
0.001
0.0001
0.1
1
10
100
1000
10 000
R (Ω)
AC01 and AC01-AT Pulse capability; E (Ws) as a function of R ()
1000
100
10
1
0.1
0.01
0.001
0.0001
0.00001
0.1
1
10
100
1000
10 000
R (Ω)
AC03 and AC03-AT Pulse capability; E (Ws) as a function of R ()
1000
100
10
1
0.1
0.01
0.001
0.0001
0.1
1
10
100
1000
10 000
R (Ω)
AC04 and AC04-AT Pulse capability; E (Ws) as a function of R ()
1000
100
10
1
0.1
0.01
0.001
0.0001
0.1
1
10
100
1000
10 000
R (Ω)
AC05 and AC05-AT Pulse capability; E (Ws) as a function of R ()
1000
100
10
1
0.1
0.01
0.001
0.0001
0.1
1
10
100
1000
10 000
R (Ω)
AC07 and AC07-AT Pulse capability; E (Ws) as a function of R ()
1000
100
10
1
0.1
0.01
0.001
0.0001
0.1
1
10
100 1000 10 000 100 000
R (Ω)
AC10 and AC10-AT Pulse capability; E (Ws) as a function of R ()
Revision: 14-Mar-17
6
Document Number: 28730
For technical questions, contact: ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000