English
Language : 

IL300 Datasheet, PDF (5/15 Pages) Siemens Semiconductor Group – LINEAR OPTOCOUPLER
VISHAY
IL300
Vishay Semiconductors
Coupler
Parameter
Input- output capacitance
K1, Servo gain (IP1/IF)
Servo current, see Note 1,2
K2, Forward gain (IP2/IF)
Forward current
K3, Transfer gain (K2/K1) see
Note 1,2
Transfer gain linearity
Photoconductive Operation
Frequency response
Phase response at 200 kHz
Test condition
VF = 0 V, f = 1.0 MHz
IF = 10 mA, Vdet = - 15 V
IF = 10 mA, Vdet = - 15 V
IF = 10 mA, Vdet = - 15 V
IF = 10 mA, Vdet = - 15 V
IF = 10 mA, Vdet = - 15 V
IF = 1.0 to 10 mA
IF = 1.0 to 10 mA,
Tamb = 0 °C to 75 °C
Symbol
K1
IP1
K2
IP2
K3
∆K3
IFq = 10 mA, MOD = ± 4.0 mA,
RL = 50 Ω
Vdet = - 15 V
BW (-3 db)
Min
0.0050
0.0036
0.56
Typ.
1.0
0.007
70
0.007
70
1.00
± 0.25
± 0.5
200
-45
Max
0.011
0.011
1.65
Unit
pF
µA
µA
K2/K1
%
%
KHz
Deg.
1. Bin Sorting:
K3 (transfer gain) is sorted into bins that are ± 6 % , as follows:
Bin A = 0.557 - 0.626
Bin B = 0.620 - 0.696
Bin C = 0.690 - 0.773
Bin D = 0.765 - 0.859
Bin E = 0.851 - 0.955
Bin F = 0.945 - 1.061
Bin G = 1.051 - 1.181
Bin H = 1.169 - 1.311
Bin I = 1.297 - 1.456
Bin J = 1.442 - 1.618
K3 = K2/K1. K3 is tested at IF = 10 mA, Vdet = - 15 V.
2. Bin Categories: All IL300s are sorted into a K3 bin, indicated by an alpha character that is marked on the part. The bins range from "A"
through "J".
The IL300 is shipped in tubes of 50 each. Each tube contains only one category of K3. The category of the parts in the tube is marked on
the tube label as well as on each individual part.
3. Category Options: Standard IL300 orders will be shipped from the categories that are available at the time of the order. Any of the ten
categories may be shipped. For customers requiring a narrower selection of bins, four different bin option parts are offered.
IL300-DEFG: Order this part number to receive categories D,E,F,G only.
IL300-EF: Order this part number to receive categories E, F only.
IL300-E: Order this part number to receive category E only.
Switching Characteristics
Parameter
Switching time
Rise time
Fall time
Test condition
∆IF = 2.0 mA, IFq = 10 mA
Symbol
Min
tr
tf
tr
tf
Typ.
Max
Unit
1.0
µs
1.0
µs
1.75
µs
1.75
µs
Document Number 83622
Rev. 1.4, 26-Oct-04
www.vishay.com
5