English
Language : 

UFB80FA20 Datasheet, PDF (4/7 Pages) Vishay Siliconix – Insulated Ultrafast Rectifier Module, 80 A
VS-UFB80FA20
Vishay Semiconductors Insulated Ultrafast Rectifier Module, 80 A
175
150
125
DC
100
75 Square Wave (d = 0.5)
Rated Vr applied
50
25
0
0 20 40 60 80 100 120
IF(AV) - Average Forward Current
Fig. 5 - - Maximum Allowable Case Temperature vs. Avarage
Forward Current (Per Leg)
80
70
60
50
RMS Limit
40
D = 0.05
30
D = 0.10
20
D = 0.20
D = 0.33
10
D = 0.50
DC
0
0 10 20 30 40 50 60 70 80
IF(AV) - Average Forward Current (A)
Fig. 6 - Forward Power Loss Characteristics (Per Leg)
Note
(1) Formula used: TC = TJ - (Pd + PdREV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = 80 % rated VR
70
If = 30 A
60
Vrr = 100 V
50
TJ = 125 ˚ C
40
30
TJ = 25 ˚ C
20
10
100
1000
dIF/dt (A/μs)
Fig. 7 - - Typical Reverse Recovery Time vs. dIF/dt
550
500
450
400
350
300
250
200
150
100
50
0
100
If = 30 A
Vrr = 100 V
TJ = 125 °C
TJ = 25 °C
dIF/dt (A/μs)
Fig. 8 - - Typical Stored Charge vs. dIF/dt
1000
www.vishay.com
4
For technical questions, contact: indmodules@vishay.com
Document Number: 93607
Revision: 12-May-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000