English
Language : 

UFB200CB40P Datasheet, PDF (4/7 Pages) Vishay Siliconix – Not Insulated SOT-227 Power Module
UFB200CB40P
Vishay High Power Products
Not Insulated SOT-227 Power Module
Ultrafast Rectifier, 200 A
180
160
140
DC
120
100
80 Square wave (D = 0.50)
60 80 % rated VR applied
40
20 See note (1)
0
0 40 80 120 160 200 240 280 320 360 400
IF(AV) - Average Forward Current (A)
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current (Per Leg)
350
300
250
200
RMS limit
150
D = 0.20
100
D = 0.25
D = 0.33
DC
D = 0.50
50
D = 0.75
0
0 20 40 60 80 100 120 140 160 180 200 220
IF(AV) - Average Forward Current (A)
Fig. 6 - Forward Power Loss Characteristics (Per Leg)
250
230
VR = 100 V
210
IF = 50 A
190
TJ = 125 °C
170
150
130
110
TJ = 25 °C
90
70
50
100
1000
dIF/dt (A/µs)
Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt
4000
3500
3000
VR = 100 V
IF = 50 A
TJ = 125 °C
2500
2000
1500
1000
TJ = 25 °C
500
0
100
1000
dIF/dt (A/µs)
Fig. 8 - Typical Reverse Recovery Charge vs. dIF/dt
50
VR = 100 V
IF = 50 A
40
30
TJ = 125 °C
20
TJ = 25 °C
10
0
100
1000
dIF/dt (A/µs)
Fig. 9 - Typical Reverse Recovery Current vs. dIF/dt
Note
(1) Formula used: TC = TJ - (Pd + PdREV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = 80 % rated VR
www.vishay.com
4
For technical questions, contact: indmodules@vishay.com
Document Number: 94276
Revision: 16-Jul-09