English
Language : 

HCTF Datasheet, PDF (4/5 Pages) Vishay Siliconix – High Current Thermal Fuse
www.vishay.com
TEST PROCEDURES AND REQUIREMENTS
EN 60115-1
CLAUSE
IEC 60068-2
TEST
METHOD
TEST
PROCEDURE
4.22
6 (Fc)
Vibration
f1: 10 Hz; f2: 2000 Hz
amplitude ± 1.5 mm or
acceleration 50 m/s2 (5 g),
whatever is less severe.
20 min/cycle (f1-f2-f1);
10 cycles each for 3 axes
4.40
-
ESD;
Human body model
acc. to IEC 61340-3-1
U = 4 kV; C = 100 pF; R = 1.5 k;
3 pos. + 3 neg.
Unpowered;
-
-
Time until opening
pre-heated at 200 °C
oil bath at 275 °C ± 5 K
4.16
21 (Ua1)
Robustness of
terminations
Tensile force
(40 ±4) N;
10 s
4.35
-
Flammability
Needle flame test; 10 s
HCTF Series
Vishay Beyschlag
REQUIREMENTS
R  0.2 m
R  0.2 m
 2.0 min
R  0.2 m
No burning after 30 s
Revision: 10-Apr-13
4
Document Number: 28798
For technical questions, contact: fuse@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000