English
Language : 

DG441 Datasheet, PDF (4/9 Pages) Intersil Corporation – Monolithic, Quad SPST, CMOS Analog Switches
DG441/442
Vishay Siliconix
SPECIFICATIONSa FOR SINGLE SUPPLY
Parameter
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 12 V, V- = 0 V
VIN = 2.4 V, 0.8 Vf
A Suffix
D Suffix
- 55 to 125 °C - 40 to 85 °C
Tempb Typc Mind Maxd Mind Maxd Unit
Analog Switch
Analog Signal Rangee
VANALOG
Full
0
12
0
12 V
Drain-Source
On-Resistance
rDS(on)
IS = - 10 mA, VD = 3 V, 8 V
V+ = 10.8 V
Room 100
Full
160
200
160
200
Ω
Dynamic Characteristics
Turn-On Time
Turn-Off Time
tON
RL = 1 kΩ, CL = 35 pF
Room 300
tOFF
VS = 8 V
See Figure 2
Room 60
450
450
ns
200
200
Charge Injection
Q
CL = 1nF, Vgen = 6 V, Rgen = 0 Ω Room
2
pC
Power Supplies
Positive Supply Current
I+
Full
15
100
100
Negative Supply Current
Ground Current
I-
IGND
V+ = 13.2 V, V- = 0 V
VIN = 0 or 5 V
Room - 0.0001 - 1
Full
- 100
-1
- 100
µA
Full
- 15 - 100
- 100
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
4
Document Number: 70053
S-71241–Rev. I, 25-Jun-07