DG381B Datasheet, PDF (4/9 Pages) Vishay Siliconix – CMOS Analog Switches | |||
|
◁ |
DG381B/384B/387B/390B
Vishay Siliconix
SPECIFICATIONSa
Parameter
Analog Switch
Analog Signal Rangee
Drain-Source
On-Resistance
Source Off
Leakage Current
Drain Off
Leakage Current
Drain On
Leakage Current
Digital Control
Symbol
VANALOG
rDS(on)
IS(off)
ID(off)
ID(on)
Input Current with
Input Voltage High
IINH
Input Current with
Input Voltage Low
IINL
Dynamic Characteristics
Test Conditions Unless Specified
V+ = 15 V, Vâ = â15 V
VIN = 0.8 V or 4 Vf
Tempb
Mind
Limits
â40 to 85_C
Typc Maxd
VD = "10 V, IS = â10 mA
VS = "14 V, VD = #14 V
VS = "14 V, VD = #14 V
VD = VS = "14 V
Full
â15
15
Room
Full
30
50
75
Room
â5
"0.1
5
Hot
â100
100
Room
â5
"0.1
5
Hot
â100
100
Room
â5
"0.1
5
Hot
â100
100
VIN = 5 V
VIN = 15 V
VIN = 0 V
Room
Full
Room
Full
Room
Full
â1
â0.001
0.001
1
â1
â0.001
Turn-On Time
Turn-Off Time
Break-Before-Make Time
Charge Injection
Source-Off Capacitance
Drain-Off Capacitance
Channel-On Capacitance
Input Capacitance
Off-Isolation
Crosstalk
(Channel-to-Channel)
Power Supplies
Positive Supply Current
Negative Supply Current
Positive Supply Current
Negative Supply Current
tON
tOFF
tOPEN
Q
CS(off)
CD(off)
CD(on)
CIN
OIRR
XTALK
I+
Iâ
I+
Iâ
See Figure 2
Room
150
Room
130
See Figure 3
Room
50
CL = 0.01 mF, Rgen = 0 W Vgen = 0 V
Room
10
Room
14
f = 1 MHz; VS, VD = 0 V
Room
14
Room
40
VIN = 0 V
Room
6
f = 1 MHz
VIN = 15 V
Room
7
Room
62
VIN = 0 V, RL = 1 kW
VS = 1 Vrms, f = 500 kHz
Room
74
VIN = 4 V (One Input)
(All Others = 0)
VIN = 0.8 V (All Inputs)
Room
Full
Room
Full
Room
Full
Room
Full
0.23
1
â100
â0.001
0.001
100
â100 â0.001
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
Unit
V
W
nA
mA
ns
pC
pF
dB
mA
mA
www.vishay.com
4
Document Number: 71404
S-02968âRev. A, 22-Jan-01
|
▷ |