English
Language : 

DG2002 Datasheet, PDF (4/9 Pages) Vishay Siliconix – Low-Voltage Single SPDT Analog Switch
DG2002
Vishay Siliconix
SPECIFICATIONS V+ = 5.0 V
Parameter
Analog Switch
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 5 V, ± 10 %
VIN = 0.8 or 2.4 Ve
Limits
- 40 to 85 °C
Tempa Minb Typc Maxb Unit
Analog Signal Ranged
On-Resistance
rON Flatnessd
VNO, VNC,
VCOM
Full
0
rON
V+ = 4.5 V, VCOM = 3 V, INO, INC = 10 mA
Room
Full
rON
Flatness
V+ = 4.5 V, VCOM = 0 to V+, INO, INC = 10 mA Room
V+
V
6.4
7.8
7.4
8.8
Ω
3
Switch Off Leakage Current
INO(off),
INC(off)
ICOM(off)
V+ = 5.5 V
VNO, VNC = 1 V/4.5 V, VCOM = 4.5 V/1 V
Room
Full
Room
Full
- 1.0
- 4.0
- 1.0
- 4.0
1.0
4.0
1.0
4.0
nA
Channel-On Leakage Current ICOM(on)
V+ = 5.5 V, V+ = 5.5 V
VNO, VNC = VCOM = 1 V/4.5 V
Room - 1.0
Full - 4.0
1.0
4.0
Digital Control
Input High Voltage
Input Low Voltage
Input Capacitance
Input Current
Dynamic Characteristics
VINH
VINL
Cin
IINL or IINH
VIN = 0 or V+
Full
2.4
Full
V
0.8
Full
3
pF
Full
-1
1
µA
Turn-On Timed
Turn-Off Timed
tON
Room
Full
tOFF
VNO or VNC = 3 V, RL = 300 Ω, CL = 35 pF
Figures 1 and 2
Room
Full
8
15
16
6
13
ns
14
Break-Before-Make Timed
Charge Injectiond
td
QINJ
Room
1
CL = 1 nF, VGEN = 0 V, RGEN = 0 Ω, Figure 3 Room
4
5
10
pC
Off-Isolationd
Crosstalkd
OIRR
Room
- 69
XTALK
RL = 50 Ω, CL = 5 pF, f = 1 MHz
Room
- 69
dB
Source-Off Capacitanced
Channel-On Capacitanced
CNO(off),
CNC(off)
CON
Room
5
VIN = 0 or V+, f = 1 MHz
pF
Room
29
Power Supply
Power Supply Range
V+
4.5
5.5
V
Power Supply Current
I+
Power Consumption
PC
VIN = 0 or V+
0.01
1.0
µA
5.5 µW
Notes:
a. Room = 25 °C, Full = as determined by the operating suffix.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
c. Typical values are for design aid only, not guaranteed nor subject to production testing.
d. Guarantee by design, nor subjected to production test.
e. VIN = input voltage to perform proper function.
f. Guaranteed by 5 V leakage testing, not production tested.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
4
Document Number: 71448
S-72609-Rev. C, 24-Dec-07