English
Language : 

VS-T70HFL60S02 Datasheet, PDF (3/16 Pages) Vishay Siliconix – Fast Recovery Diodes (T-Modules), 40 A/70 A/85 A
T40HFL, T70HFL, T85HFL Series
Fast Recovery Diodes
(T-Modules), 40 A/70 A/85 A
Vishay Semiconductors
REVERSE RECOVERY CHARACTERISTICS
PARAMETER SYMBOL
TEST CONDITIONS (1)
T40HFL
S02 S05 S10
Maximum reverse
recovery time
trr
TJ = 25 °C, -dIF/dt = 100 A/μs 70
IF = 1 A to VR = 30 V
TJ = 25 °C, -dIF/dt = 25 A/μs
200
IFM = π x rated IF(AV), VR = - 30 V
110 270
500 1000
Maximum reverse
recovery charge
Qrr
TJ = 25 °C, -dIF/dt = 100 A/μs 0.25 0.4 1.35
IF = 1 A to VR = 30 V
TJ = 25 °C, -dIF/dt = 25 A/μs
0.55 2.0 8.0
IFM = π x rated IF(AV), VR = - 30 V
Note
(1) Tested on LEM 300 A diodemeter tester
T70HFL
S02 S05 S10
70 110 270
200 500 1000
0.25 0.4 1.35
0.6 2.1 8.5
T85HFL
UNITS
S02 S05 S10
80 120 290
ns
200 500 1000
0.3 0.6 1.6
μC
0.8 3.5 1.5
BLOCKING
PARAMETER
Maximum peak reverse leakage current
RMS isolation voltage
SYMBOL
IRRM
VISOL
TEST CONDITIONS
T40HFL T70HFL T85HFL UNITS
TJ = 125 °C
20
mA
50 Hz, circuit to base, all terminals
3500
V
shorted, TJ = 25 °C, t = 1 s
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
Junction operating temperature range
Storage temperature range
Maximum internal thermal resistance,
junction to case per module
Thermal resistance,
case to heatsink per module
Mounting torque ± 10 %
base to heatsink
busbar to terminal
TJ
TStg
RthJC
RthCS
DC operation
Mounting surface, flat, smooth
and greased
M3.5 mounting screws (1)
Non-lubricated threads
M5 screws terminals
Non-lubricated threads
Approximate weight
See dimensions -
link at the end of datasheet
T40HFL T70HFL T85HFL UNITS
- 40 to 125
°C
- 40 to 150
0.85
0.53
0.46
K/W
0.2
1.3 ± 10 %
Nm
3 ± 10 %
54
g
19
oz.
Case style
D-55 (T-module)
Note
(1) A mounting compound is recommended and the torque should be rechecked after a period of about 3 hours to allow for the spread of
the compound
ΔR CONDUCTION
DEVICES
SINUSOIDAL CONDUCTION AT TJ MAXIMUM
180°
120°
90°
60°
30°
T40HFL
0.06
0.08
0.10
0.14
0.24
T70HFL
0.05
0.06
0.08
0.11
0.19
T85HFL
0.04
0.05
0.06
0.09
0.15
RECTANGULAR CONDUCTION AT TJ MAXIMUM
180°
120°
90°
60°
30°
0.05
0.08
0.10
0.15
0.24
0.04
0.06
0.08
0.12
0.19
0.03
0.05
0.07
0.09
0.015
UNITS
K/W
Note
• The table above shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
Document Number: 93184 For technical questions within your region, please contact one of the following:
Revision: 19-May-10
DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
www.vishay.com
3