COMMANDS (Code sent to touch panel)
COMMAND
Automatic baud rate selection
(ignored when baud rate is jumper selected)
DC1, Ctl Q, XON Software Handshaking
DC3, Ctl S, XOFF Software Handshaking
*Enable touch panel
Disable touch panel (stop scanning)
Enable CONTINUOUS/disable TRACKING mode
*Disable CONTINUOUS and TRACKING mode
Enable TRACKING/disable CONTINUOUS mode
Enable ENTER point mode
*Disable ENTER point mode
Enable EXIT point mode
*Disable EXIT point mode
Enable automatic report transfer
*Disable automatic report transfer (scan but no report)
Enable beeper
*Disable beeper
Failed beam time-out, t = duration (0 to F) (default = 1)
*Normal X
Invert X
*Normal Y
Invert Y
Reset touch panel
Request one coordinate report
Request failed beam report
Request model number
Request software revision number
Request touch matrix size
Sound beeper, tt = duration (00 to FF)
CODE (HEX)
0D
11
13
26
27
24
25
34
22
23
20
21
29
2A
2D
2E
3At
36
37
38
39
2C
2B
28
35
30
33
2Ftt
CODE (ASCII)
CR
DC1
DC3
&
'
$
%
4
"
#
SP
!
)
*
-
.
:
6
7
8
9
.
+
(
5
0
3
/
*Indicates default condition.
COMMAND/RESPONSE DESCRIPTION
Automatic Baud Rate Selection (0D)
For most applications a jumper selected baud rate is recommended. If automatic baud rate selection is required, contact the
factory for assistance. (The autobaud command will be ignored if a specific baud rate is jumper selected.)
DC1, Ctl Q, XON Software Handshaking (11)
DC3, Ctl S, XOFF Software Handshaking (13)
RS-232 flow control is provided by these commands. Note: A shunt must be placed on Jumper A (SOFTHAND) to allow
software handshaking. Absence of a shunt requires hardware handshaking. (See also ENABLE TOUCH PANEL command.)
*Enable Touch Panel (26)
Disable Touch Panel (stop scanning) (27)
The touch panel must be enabled for normal operation. When the touch panel is disabled, commands are processed as
they are received, allowing changes in modes of operation, but discarding any report operations.
This differs from XON/XOFF software handshaking. When the touch panel receives an XOFF character (13), commands are
executed until the touch panel requires transmission of a report, then all commands received are buffered and are not
executed until an XON character is received. If the buffer becomes full, the touch panel sends XOFF.
Enable CONTINUOUS/disable TRACKING mode (24)
*Disable CONTINUOUS/disable TRACKING mode (25)
This coordinate reporting mode will continuously report the coordinates of a stylus that remains in the touch panel. This
mode can be used individually or in combination with ENTER point, or EXIT modes. The following report format is used. If