English
Language : 

TFDU6300_09 Datasheet, PDF (3/12 Pages) Vishay Siliconix – Fast Infrared Transceiver Module (FIR, 4 Mbit/s)
TFDU6300
Fast Infrared Transceiver Module (FIR, 4 Mbit/s) Vishay Semiconductors
for 2.4 V to 3.6 V Operation
ABSOLUTE MAXIMUM RATINGS
PARAMETER
TEST CONDITIONS
SYMBOL
Supply voltage range,
transceiver
Supply voltage range,
transmitter
0 V < VCC2 < 6 V
0 V < VCC1 < 6 V
VCC1
VCC2
Voltage at all I/O pins
Input currents
Output sinking current
Power dissipation
Junction temperature
Ambient temperature range
(operating)
Storage temperature range
Soldering temperature
Average output current
Repetitive pulse output current
ESD protection
Vin < VCC1 is allowed
For all pins, except IRED anode pin
See section
“Recommended Solder Profiles”
< 90 µs, ton < 20 %
Human body model
PD
TJ
Tamb
Tstg
IIRED (DC)
IIRED (RP)
Note
Reference point pin 8, (ground) unless otherwise noted.
Typical values are for design aid only, not guaranteed nor subject to production testing.
MIN.
- 0.5
- 0.5
- 0.5
- 25
- 25
1
TYP.
MAX.
6
6.5
6
10
25
500
125
+ 85
+ 85
260
150
700
UNIT
V
V
V
mA
mA
mW
°C
°C
°C
°C
mA
mA
kV
EYE SAFETY INFORMATION
STANDARD
IEC/EN 60825-1 (2007-03), DIN EN 60825-1 (2008-05) “SAFETY OF LASER PRODUCTS -
Part 1: equipment classification and requirements”, simplified method
IEC 62471 (2006), CIE S009 (2002) “Photobiological Safety of Lamps and Lamp Systems”
DIRECTIVE 2006/25/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5th April 2006
on the minimum health and safety requirements regarding the exposure of workers to risks arising from
physical agents (artificial optical radiation) (19th individual directive within the meaning of article 16(1)
of directive 89/391/EEC)
CLASSIFICATION
Class 1
Exempt
Exempt
Note
Vishay transceivers operating inside the absolute maximum ratings are classified as eye safe according the above table.
ELECTRICAL CHARACTERISTICS (1)
PARAMETER
TEST CONDITIONS
SYMBOL
MIN.
TYP.
MAX.
TRANSCEIVER
Supply voltage
Dynamic Supply current
Shutdown supply current
VCC
2.4
3.6
Receive mode only, idle
In transmit mode, add additional 85 mA (typ) for IRED current.
Add RXD output current depending on RXD load.
SIR mode
ICC
1.8
3
MIR/FIR mode
ICC
2
3.3
SD = high
T= 25 °C, not ambient light
sensitive, detector is disabled in
ISD
0.01
shutdown mode
SD = high, full specified
Shutdown supply current
temperature range, not ambient
ISD
1
light sensitive
Operating temperature range
Input voltage low (TXD, SD)
TA
- 25
VIL
- 0.5
+ 85
0.5
UNIT
V
mA
mA
µA
µA
°C
V
Document Number: 84763 For technical questions within your region, please contact one of the following:
Rev. 2.0, 04-Aug-09
irdasupportAM@vishay.com, irdasupportAP@vishay.com, irdasupportEU@vishay.com
www.vishay.com
3