English
Language : 

ST650C Datasheet, PDF (3/7 Pages) Vishay Siliconix – Phase Control Thyristors (Hockey PUK Version), 790 A
ST650C..L Series
Phase Control Thyristors Vishay High Power Products
(Hockey PUK Version), 790 A
TRIGGERING
PARAMETER
Maximum peak gate power
Maximum average gate power
Maximum peak positive gate current
Maximum peak positive gate voltage
Maximum peak negative gate voltage
DC gate current required to trigger
DC gate voltage required to trigger
DC gate current not to trigger
DC gate voltage not to trigger
SYMBOL
PGM
PG(AV)
IGM
+ VGM
- VGM
IGT
VGT
IGD
VGD
TEST CONDITIONS
TJ = TJ maximum, tp ≤ 5 ms
TJ = TJ maximum, f = 50 Hz, d% = 50
TJ = TJ maximum, tp ≤ 5 ms
TJ = - 40 °C
TJ = 25 °C
TJ = 125 °C
TJ = - 40 °C
TJ = 25 °C
TJ = 125 °C
TJ = TJ maximum
Maximum required gate trigger/
current/voltage are the lowest
value which will trigger all units
12 V anode to cathode applied
Maximum gate current/voltage
not to trigger is the maximum
value which will not trigger any
unit with rated VDRM anode to
cathode applied
VALUES
UNITS
TYP. MAX.
10.0
W
2.0
3.0
A
20
V
5.0
200 -
100 200 mA
50
-
2.5 -
1.8 3.0 V
1.1 -
10
mA
0.25
V
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
Maximum operating temperature range
TJ
Maximum storage temperature range
TStg
Maximum thermal resistance, junction to heatsink
RthJ-hs
DC operation single side cooled
DC operation double side cooled
Maximum thermal resistance, case to heatsink
RthC-hs
DC operation single side cooled
DC operation double side cooled
Mounting force, ± 10 %
Approximate weight
Case style
See dimensions - link at the end of datasheet
VALUES UNITS
- 40 to 125
°C
- 40 to 150
0.073
0.031
K/W
0.011
0.006
14 700
N
(1500)
(kg)
255
g
TO-200AC (B-PUK)
ΔRthJ-hs CONDUCTION
CONDUCTION ANGLE
SINUSOIDAL CONDUCTION
SINGLE SIDE DOUBLE SIDE
RECTANGULAR CONDUCTION
SINGLE SIDE DOUBLE SIDE
TEST CONDITIONS
180°
0.009
0.009
0.006
0.006
120°
0.011
0.011
0.011
0.011
90°
0.014
0.014
0.015
0.015
TJ = TJ maximum
60°
0.020
0.020
0.021
0.021
30°
0.036
0.036
0.036
0.036
Note
• The table above shows the increment of thermal resistance RthJ-hs when devices operate at different conduction angles than DC
UNITS
K/W
Document Number: 93738
Revision: 13-Aug-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
3