English
Language : 

SI91872 Datasheet, PDF (3/9 Pages) Vishay Siliconix – 300-mA Low-Noise LDO Regulator With Error Flag and Discharge Option
Si91872
Vishay Siliconix
SPECIFICATIONS
Parameter
Symbol
Test Conditions Unless Specified
TA = 25_C, VIN = VOUT(nom) + 1 V, IOUT = 1 mA,
CIN = 2 mF, COUT = 2.0 mF, VSD = 1.5 V
Tempa
Limits
−40 to 85_C
Minb Typc Maxb
Unit
Ripple Rejection
Dynamic Line Regulation
Dynamic Load Regulation
Thermal Shutdown Junction
Temperature
Thermal Hysteresis
Reverse current
Short Circuit Current
Shutdown
Shutdown Supply Current
SD Pin Input Voltage
Auto Discharge Resistance
SD Pin Input Currentf
SD Hysteresis
VOUT Turn-On Time
ERROR Output
ERROR High Leakage
ERROR Low Voltage
ERROR Voltage Threshold
ERROR Voltage Threshold
Hysteresis
f = 1 kHz
Room
60
DVOUT/DVIN
IOUT = 300 mA
f = 10 kHz
Room
40
dB
f = 100 kHz
Room
30
DVO(line)
VIN : VOUT(nom) + 1 V to VOUT(nom) + 2 V
tr/tf = 2 ms, IOUT = 300 mA
Room
20
mV
DVO(load)
IOUT : 1 mA to 300 mA, tr/tf = 2 ms
Room
25
TJ(S/D)
THYST
IR
ISC
VIN = −6.0 V
VOUT = 0 V
Room
150
_C
Room
20
Room
1
mA
Room
700
mA
ICC(off)
VSD
R_DIS
IIN(SD)
VHYST(SD)
tON
VSD = 0 V
High = Regulator ON (Rising)
Low = Regulator OFF (Falling)
Si91872 Only
VSD = 1.5 V, VIN = 6 V
VSD (See Figure 1), ILOAD = 100 mA
Room
0.1
1
mA
Full
1.5
Full
VIN
V
0.4
Room
100
W
Room
0.7
mA
Full
150
mV
Room
50
ms
IOFF
VOL
VERROR
ERROR v VIN. VOUT in Regulation
Full
1
mA
ISINK = 0.5 mA
Full
0.4
V
VOUT Below VOUT(nom)g, VIN w 2 V
VOUT Falling, IOUT = 1 mA, VOUT(nom) w 2 V
Full
−2
−4
−6
VOUT(nom)g t 2 V, VIN u 2 V
Full
−4
%
VHYST(ERROR)
Room
1.5
Notes
a. Room = 25_C, Full = −40 to 85_C.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. Dropout voltage is defined as the input to output differential voltage at which the output voltage drops 2% below the output voltage measured with a 1-V
differential, provided that VIN does not not drop below 2.0 V.
e. Ground current is specified for normal operation as well as “drop-out” operation.
f. The device’s shutdown pin includes a typical 2-MW internal pull-down resistor connected to ground.
g. VOUT(nom) is VOUT when measured with a 1-V differential to VIN.
TIMING WAVEFORMS
VIN
VSD
tr v 1 mS
0V
VOUT
tON
0.95 VNOM
VNOM
FIGURE 1. Timing Diagram for Power-Up
Document Number: 72013
S-51147—Rev. F, 20-Jun-05
www.vishay.com
3