English
Language : 

PTCCL-30V Datasheet, PDF (3/6 Pages) Vishay Siliconix – 30 V to 60 V PTC Thermistors for Overload Protection
www.vishay.com
PTCCL - 30 V / 60 V Series
Vishay BCcomponents
VOLTAGE DERATING AS A FUNCTION OF AMBIENT TEMPERATURE
120
100
80
60
40
20
0
-50 -25 0 25 50 75 100 125 150 175 200
Tamb (°C)
MAXIMUM OVERLOAD CURRENT Iol max. DERATING AS A FUNCTION OF VOLTAGE
200
Iol max.
(%)
150
100
80
0
40 50 70
100 120
150
Vrated (%)
Imax. as stated in the electrical data and ordering information tables, is the maximum overload current that may flow through the
PTC when passing from the low ohmic to high ohmic state at rated voltage.
When other PTC voltages are present after tripping, the Imax. value can be derived from the above Imax. as a function of voltage
graph. Voltages below Vrated will allow higher overload currents to pass the PTC.
TYPICAL TRIP-TIME AS A FUNCTION OF TRIP CURRENT RATIO
102
ts
Curve 1: Ø Dmax. = 20.5 mm
Curve 2: Ø Dmax. = 16.5 mm
10
Curve 3: Ø Dmax. = 12.5 mm
Curve 4: Ø Dmax. = 10.5 mm
Curve 5: Ø Dmax. = 8.5 mm
1
Curve 6: Ø Dmax. = 7.0 mm
(1)
(2)
(3)
Curve 7: Ø Dmax. = 5.0 mm
(4)
(5)
Measured in accordance
10-1
(6)
(7)
with “IEC 60 738”.
12
4
6
8
10
12
14 It/Int 16
Trip-Time or Switching Time (ts)
To check the trip-time for a specific PTC, refer to the Electrical Data and Ordering Information tables for the value Int. Divide the
overload or trip current by this Int and you realize the factor It/Int. This rule is valid for any ambient temperature between 0 °C
and 85 °C. Adapt the correct non-trip current with the appropriate curve in the Current Deviation as a Function of the Ambient
Temperature graph. The relationship between the It/Int factor and the switching time is a function of the PTC diameter; see the
above graphs.
Example
What will be the trip-time at Iol = 3 A and Tamb = 0 °C of a thermistor type PTCCL09H471DBE; 2.5 Ω; Ø Dmax. = 8.5 mm:
Int from the table: 470 mA at 25 °C
Int: 470 x 1.12 = 526 mA (at 0 °C)
Overload current = 3 A; factor It/Int: 3/0.526 = 5.70. In the Typical trip-time as a function of trip current ratio graph, at the 8.5 mm
line and It/Int = 5.70, the typical trip-time is 1.7 s.
Revision: 21-Sep-15
3
Document Number: 29085
For technical questions, contact: nlr@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000