English
Language : 

K3020P Datasheet, PDF (3/9 Pages) Vishay Siliconix – Optocoupler with Phototriac Output
Electrical Characteristics (Tamb = 25°C)
Input (Emitter)
Parameter
Forward voltage
Junction capacitance
Test Conditions
IF = 50 mA
VR = 0, f = 1 MHz
Symbol
VF
Cj
K3020P(G) Series
Vishay Telefunken
Min.
Typ.
Max.
Unit
1.25
1.6
V
50
pF
Output (Detector)
Parameter
Test Conditions
Forward peak off-state
voltage (repetitive)
IDRM = 100 nA
Peak on-state voltage
Critical rate of rise of
off-state voltage
ITM = 100 mA
IFT = 0, IFT = 30 mA
1) Test voltage must be applied within dv/dt ratings
Symbol Min.
Typ.
Max.
Unit
VDRM 1)
400
V
VTM
1.5
(dv/dt)cr
10
(dv/dt)crq 0.1
0.2
3
V
V/ms
V/ms
Coupler
Parameter
Test Conditions
Type Symbol Min.
W Emitting diode trigger VS = 3 V, RL = 150 K3020P(G)
IFT
current
K3021P(G)
IFT
K3022P(G)
IFT
K3023P(G)
IFT
Holding current
IF = 10 mA, VS ≥ 3 V
IH
Note: IFT is defined as a minimum trigger current
Typ. Max. Unit
15
30
mA
8
15
mA
5
10
mA
2
5
mA
100
mA
RS
Test condition:
dv/dtcr
VS = 2/3 VDRM
(Sine wave)
V~
RL = 33 kΩ
IFT
dv/dtcrq
RL
Veff = 30 V
(Sine wave)
RL = 2 kΩ
95 10813
Figure 1. Test circuit for dv/dtcr and dv/dtcrp
Document Number 83505
Rev. A5, 13–Sep–99
www.vishay.de • FaxBack +1-408-970-5600
3 (9)