English
Language : 

DG2747 Datasheet, PDF (3/8 Pages) Vishay Siliconix – 0.4-Ω, Low Voltage, Dual SPST Analog Switch
DG2747/DG2748/DG2749
Vishay Siliconix
SPECIFICATIONS V+ = 3 V
Parameter
Analog Switch
Analog Signal Ranged
On-Resistance
Symbol
Vanalog
RDS(on)
RON Matchd
RON Resistance Flatnessd
Switch Off Leakage
Current
ΔRON
RON
flatness
INO/NC(off)
ICOM(off)
Test Conditions
Unless Otherwise Specified
V+ = 3 V, ± 10 %,VIN = 0.4 V or 1.4 Ve
Temp.a
Limits
- 40 to 85 °C
Min.b Typ.c Max.b
RDS(on)
Full
0
V+ = 2.7 V, INO/NC = 100 mA, VCOM = 0.5 V
V+ = 2.7 V, INO/NC = 100 mA, VCOM = 1.5 V
Room
V+ = 2.7 V, INO/NC = 100 mA, VCOM = 0.5 V
Full
V+ = 2.7 V, INO/NC = 100 mA, VCOM = 1.5 V
V+ = 2.7 V, INO/NC = 100 mA,
VCOM = 0.5 V, 1.5 V
Room
V+ = 2.7 V, INO/NC = 100 mA,
VCOM = 0.5 V, 1.5 V
Room
Room
-2
V+
0.4
0.6
0.7
0.03
0.1
0.2
2
V+ = 4.3 V, VNO/NC = 1.0 V/3.3 V,
Full
- 10
10
VCOM = 3.3 V/1.0 V
Room
-2
2
Full
- 10
10
Unit
V
Ω
nA
Channel-On Leakage
Current
ICOM(on)
V+ = 4.3 V, VNO/NC = VCOM = 3.3 V/1.0 V
Room
Full
-2
- 10
2
10
Digital Control
Input High Voltage
Input Low Voltage
Input Current
Dynamic Characteristics
VINH
VINL
IINL or IINH
VIN = 0 or V+
Full
1.4
Full
Full
-1
V
0.4
1
µA
Turn-On Timee
tON
Turn-Off Timee
Charge Injectiond
Off-Isolationd
tOFF
Q
OIRR
Crosstalkd
3 dB bandwidthd
Source Off Capacitanced
Drain Off Capacitanced
Drain On Capacitanced
Total Harmonic Distortiond
XTALK
CNX(off)
CCOM(off)
CCOM(on)
THD
V+ = 2.7 V to 3.6 V, VNO or VNC = 1.5 V,
RL = 50 Ω, CL = 35 pF
CL = 1 nF, RGEN = 0 Ω, VGEN = 0 V
RL = 50 Ω, CL = 5 pF, f = 1 MHz
RL = 50 Ω, CL = 5 pF, f = 100 kHz
RL = 50 Ω, CL = 5 pF, f = 1 MHz
RL = 50 Ω, CL = 5 pF, f = 100 kHz
RL = 50 Ω, CL = 5 pF
f = 1 MHz, VNX = 0 V
f = 1 MHz, VCOM = 0 V
f = 1 MHz, VCOM = VNX = 0 V
V+ = 2.7 V to 3.6 V, VIN = 0.5 Vp-p
F = 20 Hz to 20 kHz
Room
Full
Room
Full
Room
Room
Room
Room
Room
Room
Room
14
25
27
ns
12
25
27
10
pC
- 52
- 72
dB
- 80
- 100
78
MHz
75
55
pF
100
0.03
%
Power Supply
Power Supply Range
V+
1.6
4.3
V
Power Supply Current
I+
VIN = 0 or V+
Full
1.0
µA
Notes:
a. Room = 25 °C, Full = as determined by the operating suffix.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
c. Typical values are for design aid only, not guaranteed nor subject to production testing.
d. Guarantee by design, not subjected to production test.
e. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 69977
S-80899-Rev. A, 21-Apr-08
www.vishay.com
3