English
Language : 

DG2727 Datasheet, PDF (3/8 Pages) Vishay Siliconix – 0.65-ohm, Low Voltage, Negative Swing Capable, Dual SPST Analog Switch
DG2727, DG2728, DG2729
Vishay Siliconix
SPECIFICATIONS V+ = 3 V
Parameter
Analog Switch
Analog Signal Ranged
On-Resistance
RON Match
RON Resistance Flatness
Switch Off Leakage
Current
Symbol
Vanalog
RON
ΔRON
RON
flatness
IS(off)
ID(off)
Test Conditions
Limits
Unless Otherwise Specified
- 40 °C to 85 °C
V+ = 3 V, ± 10 %,VIN = 0.4 V or 1.2 Ve
Temp.a
Min.b
Typ.c Max.b Unit
V+ = 2.7 V, ID = 100 mA,
VS = - 1.6 V, - 1 V, 0 V, 2 V, 2.7 V
V+ = 2.7 V, ID = 100 mA,
VS = - 1.6 V, - 1 V, 0 V, 2 V, 2.7 V
V+ = 2.7 V, ID = 100 mA,
VS = - 1.6 V, - 1 V, 0 V, 2 V, 2.7 V
V+ = 2.7 V, VS = - 1.8 V, 2.4 V
VD = 0 V
Full V+ - 4.3 V
V+
V
Room
0.65
1.0
Full
1.15
Room
0.1
Ω
Room
0.2
0.3
Room
Full
Room
Full
- 100
- 500
- 100
- 500
100
500
100
nA
500
Channel-On Leakage
Current
ID(on)
V+ = 2.7 V, VS = VD = - 1.8 V, 2.4 V
Room
Full
- 100
- 500
100
500
Digital Control
High Level Input Voltage
VINH
Low Level Input Voltage
Input Current
Dynamic Characteristics
VINL
IINL or IINH
V+ = 1.6 V to 2.6 V
V+ = 2.7 V to 4.3 V
V+ = 1.6 V to 2.6 V
V+ = 2.7 V to 4.3 V
VIN = 0 or V+
1.0
1.2
Full
-1
V
0.3
0.4
1
µA
Turn-On Time
Turn-Off Time
Room
tON
V+ = 1.6 V to 4.3 V, VS = 1.5 V,
Full
tOFF
RL = 50 Ω, CL = 35 pF
Room
Full
38
67
72
ns
14
40
42
Break-Before-Make Time
(DG2729 only)
tBBM
Full
2
14
Charge Injectiond
Q
CL = 1 nF, RGEN = 0 Ω, VGEN = 0 V
Room
1.2
Off-Isolationd
Crosstalkd
3 dB Bandwidthd
Total Harmonic Distortiond
Source Off Capacitanced
OIRR
XTALK
THD
CS(off)
RL = 50 Ω, CL = 5 pF, f = 1 MHz
RL = 50 Ω, CL = 5 pF, f = 100 kHz
RL = 50 Ω, CL = 5 pF, f = 1 MHz
RL = 50 Ω, CL = 5 pF, f = 100 kHz
RL = 50 Ω, CL = 5 pF
RL = 600 Ω, 0.5 Vp-p, f = 20 Hz to 20 kHz
f = 1 MHz, VS = 0 V
Room
Room
Room
Room
- 58
- 76
- 64
- 82
252
0.006
31
Drain Off Capacitanced
CD(off)
f = 1 MHz, VD = 0 V
Room
31
Drain On Capacitanced
CD(on)
f = 1 MHz, VD = VS = 0 V
Room
46
Power Supply
ns
pC
dB
MHz
%
pF
Power Supply Range
V+
1.6
4.3
V
Power Supply Current
I+
VIN = 0 or V+
Full
1.0
µA
Notes:
a. Room = 25 °C, Full = as determined by the operating suffix.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
c. Typical values are for design aid only, not guaranteed nor subject to production testing.
d. Guarantee by design, not subjected to production test.
e. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 69049
S09-0557-Rev. A, 13-Apr-09
www.vishay.com
3