SPECIFICATIONS V+ = 5 V
Parameter
Analog Switch
Analog Signal Ranged
On-Resistance
RON Match
RON Resistance Flatness
Switch Off Leakage
Current
Symbol
Vanalog
RDS(on)
ΔRON
RON
flatness
ISX(off)
ICOM(off)
Test Conditions
Unless Otherwise Specified
V+ = 5 V, ± 10 %,VIN = 0.6 V or 1.8 Ve
RDS(on)
V+ = 4.5 V, ISX = 100 mA, VCOM = 2.5 V
V+ = 4.5 V, ISX = 100 mA, VCOM = 2.5 V
V+ = 4.5 V, ISX = 100 mA, VCOM = 2.5 V
V+ = 4.5 V, ISX = 100 mA,
VCOM = 0.5 V, 2.5 V
V+ = 5.5 V, VSX = 1 V/4.5 V,
VCOM = 4.5 V/1 V
Temp.a
Limits
- 40 °C to 85 °C
Min.b Typ.c Max.b
Unit
Full
0
V+
V
Room
0.8
1.1
Full
1.5
Room
0.1
Ω
Room
0.2
0.6
Room
Full
Room
Full
- 20
- 120
- 20
- 120
20
120
20
nA
120
Channel-On Leakage
Current
ICOM(on)
V+ = 4.3 V, VSX = VCOM = 4.5 V/1 V
Room
Full
- 20
- 120
20
120
Power Down Leakage
Room
-1
0.001
1
V+ = 0 V, VSX = 0 V/5.5 V, VCOM = 5.5 V/0 V
Full
- 25
µA
25
Digital Control
Input High Voltage
Input Low Voltage
Input Capacitance
Input Current
Dynamic Characteristics
VINH
VINL
CIN
IINL or IINH
V+ = 2.7 V
V+ = 4.5 V
f = 1 MHz, VINx = 0 V
VIN = 0 or V+
Full
1.6
Full
1.8
V
Full
0.6
Room
5
pF
Full
-1
1
µA
Break-Before-Make Timee
tBBM
Enable Turn-On Timee
tON
Enable Turn-Off Timee
Charge Injectiond
Off-Isolationd
Crosstalkd
- 3 dB Bandwidthd
Source Off Capacitanced
Drain Off Capacitanced
Drain On Capacitanced
Total Harmonic Distortiond
tOFF
Q
OIRR
XTALK
BW
CSX(off)
CCOM(off)
CCOM(on)
THD
V+ = 5.0 V, VSX = V+,
RL = 50 Ω, CL = 35 pF (see figure 2)
V+ = 5.0 V, VSX = V+,
RL = 50 Ω, CL = 35 pF (see figure 1)
CL = 1 nF, RGEN = 0 Ω, VGEN = 0 V
RL = 50 Ω, CL = 5 pF, f = 1 MHz
RL = 50 Ω, CL = 5 pF, f = 1 MHz
RL = 50 Ω, CL = 5 pF
f = 1 MHz, VNX = 0 V
f = 1 MHz, VCOM = 0 V
f = 1 MHz, VCOM = VNX = 0 V
V+ = 5 V, VIN = 1 VRMS, RL = 600 Ω
f = 20 Hz to 20 kHz
Room
8
Full
14
Room
53
75
Full
85
Room
40
60
Full
70
Room
27
- 59
Room
- 64
Room
105
Room
17
Room
51
Room
70
Room
0.008
ns
pC
dB
MHz
pF
%
Power Supply
Power Supply Range
V+
1.6
5.5
V
Power Supply Current
I+
VIN = 0 or V+
Full
1.0
µA
Notes:
a. Room = 25 °C, Full = as determined by the operating suffix.
b. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
c. Typical values are for design aid only, not guaranteed nor subject to production testing.
d. Guarantee by design, not subjected to production test.
e. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 68831
S09-0293-Rev. B, 23-Feb-09
www.vishay.com
3