English
Language : 

DG2011 Datasheet, PDF (3/7 Pages) Vishay Siliconix – Low-Voltage, Low rON, Single SPDT Analog Switch In SC-89 Package
DG2011
Vishay Siliconix
SPECIFICATIONS (V+ = 3 V)
Parameter
Analog Switch
Symbol
Test Conditions
Otherwise Unless Specified
V+ = 3 V, "10%, VIN = 0.4 or 2.0 Ve
Tempa
Limits
−40 to 85_C
Minb Typc Maxb
Unit
Analog Signal Ranged
On-Resistance
rON Match
rON Flatness
Switch Off Leakage Current
Channel-On Leakage Current
VNO, VNC,
VCOM
rON
DrON
rON
Flatness
V+ = 2.7 V, VCOM = 0.9 V/1.5 V
INO, INC = 50 mA
Full
0
Room
Full
Room
Room
V+
V
1.8
2.7
2.9
0.2
W
0.2
0.5
INO(off),
INC(off)
ICOM(off)
V+ = 3.3 V, VNO, VNC = 1 V/3 V
VCOM = 3 V/1 V
Room
−1
Full
−10
Room
−1
Full
−10
1
10
1
10
nA
ICOM(on)
V+ = 3.3 V, VNO, VNC = VCOM = 1 V/3 V
Room
Full
−1
−10
1
10
Digital Control
Input High Voltage
Input Low Voltage
Input Capacitance
Input Current
Dynamic Characteristics
VINH
VINL
Cin
IINL or IINH
VIN = 0 or V+
Full
1.6
Full
V
0.4
Full
4
pF
Full
1
1
mA
Turn-On Time
Turn-Off Time
Break-Before-Make Time
Charge Injectiond
Off-Isolationd
Crosstalkd
NO, NC Off Capacitanced
Channel-On Capacitanced
Power Supply
tON
Room
Full
tOFF
VNO or VNC = 2.0 V, RL = 300 W, CL = 35 pF
Room
Full
tBBM
QINJ
OIRR
XTALK
CNO(off),
CNC(off)
CON
CL = 1 nF, VGEN = 0 V, RGEN = 0 W
RL = 50 W, CL = 5 pF, f = 1 MHz
VIN = 0 or V+, f = 1 MHz
Room
1
Room
Room
Room
Room
Room
45
75
77
29
59
62
ns
16
2
pC
−62
dB
−68
28
pF
84
Power Supply Range
V+
Power Supply Current
I+
Power Consumption
PC
VIN = 0 or V+
1.8
5.5
V
0.01
1.0
mA
3.3
mW
Notes:
a. Room = 25°C, Full = as determined by the operating suffix.
b. Typical values are for design aid only, not guaranteed nor subject to production testing.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Guarantee by design, nor subjected to production test.
e. VIN = input voltage to perform proper function.
f. Guaranteed by 5-V leakage testing, not production tested.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Document Number: 70102
S-50509—Rev. E, 21-Mar-05
www.vishay.com