AC03 Datasheet, PDF (3/4 Pages) celduc-relais – REED SWITCH NORMALY OPEN, DRY CONTACT | |||
|
◁ |
www.vishay.com
AC03 Safety (AC03..CS)
Vishay Draloric
PERFORMANCE
TEST
PERMISSIBLE CHANGE
Climatic Category (LCT/UCT/Days)
40/200/56
Climatic Sequence, IEC 60115-1, 4.23
ïR = ± (1 % R + 0.05 ï)
Damp Heat, Steady State, IEC 60115-1, 4.24
(40 ± 2) °C, 56 days, (93 ± 3) % RH
ïR = ± (5 % R + 0.1 ï)
Endurance at room temperature (116 % P70), 1000 h,
IEC 60115-1, 4.25.2
ïR = ± (5 % R + 0.1 ï)
Endurance at UCT, 200 °C (30 % P70), 1000 h, IEC 60115-1, 4.25.3
Resistance to Soldering Heat, IEC 60115-1, 4.18
(260 ± 5) °C, (10 ± 1) s
ïR = ± (5 % R + 0.1 ï)
ïR = ± (0.5 % R + 0.05 ï)
Robustness of Termination, IEC 60115-1, 4.16
ïR = ± (0.5 % R + 0.05 ï)
Short Time Overload, IEC 60115-1, 4.13
10 x Rated Power for 5 s
ïR = ± (2 % R + 0.1 ï)
Fail safe mains Fusing at 240V VRMS
Resistance > 100 kï, fusing time < 2 s
(fusing without flames, explosion or smoke)
Notes
⢠Please see document âVishay Material Category Policyâ: www.vishay.com/doc?99902
⢠Refer www.vishay.com/doc?28730 for other details
⢠For further information, please contact: ww1resistors@vishay.com
Revision: 24-May-12
3
Document Number: 28861
For technical questions, contact: ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
|
▷ |