English
Language : 

UGE5HT Datasheet, PDF (2/4 Pages) Vishay Siliconix – Ultrafast recovery time
www.vishay.com
UGE5HT, UGE5JT
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TC = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
SYMBOL
UGE5HT
UGE5JT
TJ = 25 °C
1.75
Max. instantaneous forward voltage
IF = 5 A
VF
TJ = 125 °C
1.50
TJ = 25 °C
30
Max. DC reverse current at VRWM
TJ = 100 °C
IR
800
TJ = 125 °C
4.0
Max. reverse recovery time
IF = 0.5 A, IR = 1.0 A,
Irr = 0.25 A
IF = 1.0 A, dI/dt = 50 A/μs,
trr
VR = 30 V, Irr = 0.1 IRM
25
50
Typical softness factor (tb/ta)
IF = 5.0 A, dI/dt = 240 A/μs,
VR = 400 V, Irr = 0.1 IRM
S
0.9
Max. reverse recovery current
IF = 5.0 A, dI/dt = 40 A/μs,
VR = 400 V, TC = 125 °C
IF = 5.0 A, dI/dt = 240 A/μs,
IRM
VR = 400 V, TC = 125 °C
3.0
9.0
Peak forward recovery time
IF = 5.0 A, dI/dt = 64 A/μs,
VF = 1.1VF max.
trr
500
UNIT
V
μA
mA
ns
-
A
ns
THERMAL CHARACTERISTICS (TC = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
UGE5HT
UGE5JT
Typical thermal resistance from junction to case
RJC (1)
3.0
Notes
(1) Pulse test: 300 μs pulse width, 1 % duty cycle
UNIT
°C/W
ORDERING INFORMATION (Example)
PACKAGE
PREFERRED P/N
UNIT WEIGHT (g)
TO-220AC
UGE5JT-E3/45
1.80
PACKAGE CODE
45
BASE QUANTITY
50/tube
DELIVERY MODE
Tube

RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted)
8
7
6
5
UGE
4
3
2
1
0
0 25 50 75 100 125 150 175
Case Temperature (°C)
Fig. 1 - Forward Current Derating Curve
100
80
60
40
20
0
1
10
100
Number of Cycles at 60 Hz
Fig. 2 - Max. Non-Repetitive Peak Forward Surge Current
Revision: 23-Feb-16
2
Document Number: 87721
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000