English
Language : 

TCLT1100 Datasheet, PDF (2/9 Pages) Vishay Siliconix – Optocoupler, Phototransistor Output, SOP-6L5, Half Pitch, Long Mini-Flat Package
TCLT11..Series
Vishay Semiconductors Optocoupler, Phototransistor Output,
SOP-6L5, Half Pitch, Long Mini-Flat
Package
ABSOLUTE MAXIMUM RATINGS (1)
PARAMETER
TEST CONDITION
SYMBOL
VALUE
UNIT
INPUT
Reverse voltage
Forward current
Forward surge current
Power dissipation
Junction temperature
OUTPUT
VR
6
V
IF
60
mA
tP ≤ 10 µs
IFSM
1.5
A
Pdiss
100
mW
Tj
125
°C
Collector emitter voltage
VCEO
70
V
Emitter collector voltage
VECO
7
V
Collector current
IC
50
mA
Collector peak current
tP/T = 0.5, tP ≤ 10 ms
ICM
100
mA
Power dissipation
Pdiss
150
mW
Junction temperature
Tj
125
°C
COUPLER
Isolation test voltage (RMS)
Total power dissipation
Operating ambient temperature range
Storage temperature range
Soldering temperature (2)
VISO
Ptot
Tamb
Tstg
Tsld
5000
250
- 40 to + 100
- 40 to + 100
260
VRMS
mW
°C
°C
°C
Notes
(1) Tamb = 25 °C, unless otherwise specified.
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not
implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum
ratings for extended periods of the time can adversely affect reliability.
(2) Refer to reflow profile for soldering conditions for surface mounted devices.
ELECTRICAL CHARACTERISTICS
PARAMETER
TEST CONDITION
SYMBOL
MIN.
TYP.
MAX.
UNIT
INPUT
Forward voltage
Junction capacitance
OUTPUT
IF = ± 50 mA
VF
VR = 0 V, f = 1 MHz
Cj
1.25
1.6
V
50
pF
Collector emitter voltage
IC = 1 mA
VCEO
70
Emitter collector voltage
IE = 100 µA
VECO
7
Collector emitter cut-off current
VCE = 20 V, IF = 0 A, E = 0
ICEO
COUPLER
V
V
10
100
nA
Collector emitter saturation voltage
Cut-off frequency
Coupling capacitance
IF = 10 mA, IC = 1 mA
VCE = 5 V, IF = 10 mA,
RL = 100 Ω
f = 1 MHz
VCEsat
fc
Ck
0.3
V
110
kHz
0.3
pF
Note
Tamb = 25 °C, unless otherwise specified.
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
www.vishay.com
2
For technical questions, contact: optocoupler.answers@vishay.com
Document Number: 83514
Rev. 2.1, 09-Jan-08