English
Language : 

Si9139 Datasheet, PDF (2/17 Pages) Vishay Siliconix – Multi-Output, Individual On/Off Control Power-Supply Controller
Si9139
Vishay Siliconix
New Product
ABSOLUTE MAXIMUM RATINGS
VIN to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 to +36 V
PGND to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±2 V
VL to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 to +6.5 V
BSTA, BSTB, BSTC to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 V to +36 V
VL Short to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous
LXA to BSTA; LXB to BSTB; LXC to BSTC . . . . . . . . . . . . . . . . . -6.5 V to 0.3 V
Inputs/Outputs to GND
(CSA, CSB, CSP, CSN) . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 V to (VL +0.3 V)
RESET, ONA, ONB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 V to +5.5 V
DLA, DLB, DLC to PGND . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 V to (VL +0.3 V)
DHA to LXA, DHB to LXB,
DHC to LXC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 V to (BSTx +0.3 V)
Continuous Power Dissipation (TA = 70_C)a
28-Pin SSOPb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762 mW
Operating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . -40 _C to 85_C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . -40 _C to 125_C
Lead Temperature (Soldering, 10 Sec.) . . . . . . . . . . . . . . . . . . . . . . . . . . 300_C
Notes
a. Device mounted with all leads soldered or welded to PC board.
b. Derate 9.52 mW/_C above 70_C.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONS
Parameter
Buck Controller A
Total Regulation (Line, Load, and Temperature)
Line Regulation
Load Regulation
Current Limit
Bandwidth
Phase Margin
Minimum Duty Cycle
Buck Controller B
Total Regulation (Line, Load, and Temperature)
Line Regulation
Load Regulation
Current Limit
Bandwidth
Phase Margin
Minimum Duty Cycle
Auxiliary Controller C
Total Regulation (Line, Load, and Temperature)
Output Voltage Set to 12 V
Line Regulation
Load Regulation
Current Limit
Bandwidth
Phase Margin
Current-Sense Common Mode Voltage Range
Feedback Input Voltage Range
Minimum Duty Cycle
Maximum Duty Cycle
www.vishay.com
2
Test Conditions
VIN = 15 V , IVL = IREF = 0 mA
TA = -40_C to 85_C, All Controllers ON
Mina
Limits
Typb
Maxa
Unit
VIN = 4.5 V to 30 V, 0 < VCS3 - VFB3 < 90 mV
-3
VIN = 6.0 V to 30 V
VIN = 4.5 V to 30 V
0 < VCS3 - VFB3 < 90 mV
0
3
±0.5
%
±1.0
±0.5
VCSA - VFBA
VOUT > 2.5 V
90
125
160
mV
VOUT < 2.5 V
100
180
L = 10 mH, C = 330 mF
50
kHz
RSENSE = 20 mW
65
_
7
%
VIN = 4.5 V to 30 V, 0 < VCS5 - VFB5 < 90 mV
-3
0
3
VIN = 6.0 V to 30 V
VIN = 4.5 V to 30 V
±0.5
%
±1.0
0 < VCSB - VFBB < 90 mV
±0.5
VCSB - VFBB
VOUT > 2.5 V
90
125
160
mV
VOUT < 2.5 V
100
180
L = 10 mH, C = 330 mF
50
kHz
RSENSE = 20 mW
65
_
7
%
VIN = 4.5 V to 30 V, 0 < VCSP - VCSN < 300 mV
R5 = 26.4 kW, R6 = 10 kW (See Figure 1)
-5
0
5
VIN = 6.0 V to 30 V
VIN = 4.5 V to 30 V
±0.5
%
±1.0
0 < VCSP - VFBN < 300 mV
±0.5
VCSP - VCSN
280
360
450
mV
L = 10 mH, C = 100 mF
10
kHz
RSENSE = 100 mW, Ccomp = 120 pF
65
_
0.0
2.1
V
0.0
2.1
VIN = 5 V
7
%
85
Document Number: 71841
S-22317—Rev. A, 16-Dec-02