FORWARD CONDUCTION
PARAMETER
SYMBOL
TEST CONDITIONS
Maximum DC output current
at case temperature
Resistive or inductive load
IO
Maximum peak, one-cycle
non-repetitive forward current
Maximum I2t for fusing
Maximum I2t for fusing
Value of threshold voltage
Forward slope resistance
Maximum forward voltage drop
RMS isolation voltage base plate
IFSM
I2t
I2t
VF(TO)
rt
VFM
VINS
t = 10 ms
t = 8.3 ms
No voltage
reapplied
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
100 % VRRM
reapplied
No voltage
reapplied
Initial TJ =
TJ maximum
t = 10 ms
t = 8.3 ms
100 % VRRM
reapplied
I2t for time tx = I2t x tx0.1  tx  10 ms, VRRM = 0 V
TJ maximum
TJ = 25 °C, IFM = 30 Apk
TJ = TJ maximum, IFM = 30 Apk
f = 50 Hz, t = 1 s
tp = 400 μs
VALUES
60
59
300
310
250
260
442
402
313
284
4.4
0.914
10.5
1.33
1.23
3000
UNITS
A
°C
A
A2s
kA2s
V
m
V
RECOVERY CHARACTERISTICS
PARAMETER
SYMBOL
TEST CONDITIONS
Reverse recovery time
TJ = 25 °C, IF = 20 A, VR = 30 V,
trr
dIF/dt = 100 A/μs
TJ = 125 °C, IF = 20 A, VR = 30 V,
dIF/dt = 100 A/μs
TJ = 25 °C, IF = 20 A, VR = 30 V,
Reverse recovery current
Irr
dIF/dt = 100 A/μs
TJ = 125 °C, IF = 20 A, VR = 30 V,
dIF/dt = 100 A/μs
TJ = 25 °C, IF = 20 A, VR = 30 V,
Reverse recovery charge
Qrr
dIF/dt = 100 A/μs
TJ = 125 °C, IF = 20 A, VR = 30 V,
dIF/dt = 100 A/μs
Snap factor, typical
S
TJ = 25 °C
VALUES
160
250
10
15
1.20
2.90
0.6
UNITS
ns
A
nC
-
IFM
trr
t
dIR
dt
Qrr
IRM(REC)
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
Junction and storage
temperature range
Maximum thermal resistance
junction to case per bridge
TJ, TStg
RthJC
Typical thermal resistance,
case to heatsink per module
RthCS Mounting surface, smooth, flat and greased
Approximate weight
Mounting torque ± 10 %
Bridge to heatsink
Case style
VALUES
- 55 to 150
UNITS
°C
0.30
°C/W
0.05
30
g
1.3
Nm
SOT-227
www.vishay.com
2
For technical questions within your region, please contact one of the following:
indmodules@vishay.com
Document Number: 93050
Revision: 10-May-11
This document is subject to change without notice.