ELECTRICAL SPECIFICATIONS
Resistive Element
Electrical Travel
Resistance Range
Linear Law
Logarithmic Laws
Standard series E3
Tolerance
Standard
On Request
Power Rating
Linear
Logarithmic
Temperature Coefficient
Limiting Element Voltage (Linear Law)
Contact Resistance Variation (Linear Law)
End Resistance (Typical)
Dielectric Strength (RMS)
Insulation Resistance (500 VDC)
MECHANICAL SPECIFICATIONS
Mechanical Travel
Operating Torque (max. Ncm)
End Stop Torque (max. Ncm)
Max Tightening Torque
of Mounting Nut (Ncm)
Unit Weight (max. g)
300° ± 5°
3 typical
70
250
25 to 35
POWER RATING CHART
LIN. LAW “A”
6
LOG. LAWS “L & F”
3
SHAFT LOCKING: DBAN
The shaft locking device consists of a tapered nut tightening
a slotted notched washer against both bushing and shaft.
DBAN tightening torque is 200 Ncm, shaft locking torque
being 30 Ncm.
DBAN is also available with all special types.
This device is normally supplied in a separate bag. Can be
pre-mounted on request.
LOCATING PEG: LPRP
Location is obtained by fitting a special washer on the
potentiometer face. The peg can therefore be positioned at
90°, 180°, 270° and 360°.
cermet
270° ± 10°
1 Ω to 1 MΩ
100 Ω to 2.2 MΩ
1 - 2 - 2.5 - 5
± 20 %
± 10 % - ± 5 %
6 W at + 50 °C
3 W at + 50 °C
see Standard Resistance Element Data
350 V
3 % Rn or 0.5 Ω
0.5 Ω or 1 %
2500 V
106 MΩ
ENVIRONMENTAL SPECIFICATIONS
Temperature Range
Climatic Category
Sealing
- 55 °C to + 125 °C
55/125/56
fully sealed
container IP67
RESISTANCE LAWS
100
80
F
60
A
L
40
0
0
20
40
60 70 80
100
125 140
AMBIENT TEMPERATURE IN °C
20
0
0
20
40
60
80
100
% CLOCKWISE SHAFT ROTATION
Document Number: 51005
Revision: 05-Jun-08
For technical questions, contact: sfer@vishay.com
See also: Application notes
www.vishay.com