English
Language : 

60CPU02-F_12 Datasheet, PDF (2/7 Pages) Vishay Siliconix – Ultrafast Rectifier, FRED Pt®, 2 x 30 A
www.vishay.com
VS-60CPU02-F, VS-60CPU02-N3
Vishay Semiconductors
DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN.
TYP.
IF = 1.0 A, dIF/dt = 100 A/μs, VR = 30 V
-
30
Reverse recovery time
trr
TJ = 25 °C
-
30
TJ = 125 °C
-
47
Peak recovery current
TJ = 25 °C
IF = 30 A
-
3
IRRM
dIF/dt = - 200 A/μs
TJ = 125 °C
VR = 160 V
-
6.5
Reverse recovery charge
TJ = 25 °C
Qrr
TJ = 125 °C
-
42
-
160
MAX.
36
-
-
-
-
-
-
UNITS
ns
A
nC
THERMAL - MECHANICAL SPECIFICATIONS (TJ = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN.
TYP.
MAX.
Maximum junction and
storage temperature range
TJ, TStg
- 65
-
175
Thermal resistance,
junction to case per leg
RthJC
-
0.6
1.0
Thermal resistance,
junction to ambient per leg
RthJA
Typical socket mount
-
-
40
Thermal resistance,
case to heatsink
RthCS
Mounting surface, flat, smooth
and greased
-
0.5
-
Weight
-
6.0
-
-
0.21
-
Mounting torque
6.0
-
12
(5.0)
(10)
Marking device
Case style TO-247AC
60CPU02
UNITS
°C
°C/W
g
oz.
kgf · cm
(lbf · in)
1000
100
10
TJ = 175 °C
TJ = 125 °C
TJ = 25 °C
1
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
VF - Forward Voltage Drop (V)
Fig. 1 - Typical Forward Voltage Drop Characteristics
1000
100
10
1
0.1
0.01
TJ = 175 °C
TJ = 150 °C
TJ = 125 °C
TJ = 100 °C
TJ = 75 °C
TJ = 50 °C
TJ = 25 °C
0.001
0
50
100
150
200
VR - Reverse Voltage (V)
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage
Revision: 26-Jan-12
2
Document Number: 94657
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000