FORWARD CONDUCTION
PARAMETER
SYMBOL
TEST CONDITIONS
Maximum RMS output current
at case temperature
IO
120° rect. conduction angle
Maximum peak, one-cycle
forward. non-repetitive on state
surge current
Maximum I2t for fusing
Maximum I2√t for fusing
Value of threshold voltage
Slope resistance
Maximum forward voltage drop
Isolation voltage
ITSM
I2t
I2√t
VF(TO)
rt
VFM
VISOL
t = 10 ms
t = 8.3 ms
No voltage
reapplied
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
100 % VRRM
reapplied
No voltage
reapplied
Initial TJ = TJ maximum
t = 10 ms
t = 8.3 ms
100 % VRRM
reapplied
t = 0.1 to 10 ms, no voltage reapplied
TJ maximum
Ipk = 200 A, TJ = 25 °C, tp = 400 µs single junction
TJ = 25 °C all terminal shorted, f = 50 Hz, t = 1 s
VALUES
200
85
1800
1880
1520
1590
16.2
14.7
11.6
12.6
162
0.76
2.4
1.40
4000
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
Maximum junction operating
and storage temperature range TJ, TStg
DC operation per module
Maximum thermal resistance,
junction to case
RthJC
DC operation per junction
120° rect. conduction angle per module
120° rect. conduction angle per junction
Maximum thermal resistance,
case to heatsink per module
RthCS
Mounting surface smooth, flat and greased.
Heatsink compund thermal conductivity = 0.42 W/mK
Mounting torque ± 10 %
to heatsink
Approximate weight
A mounting compound is recommended and the torque
should be rechecked after a period of 3 hours to allow
for the spread of the compound. Lubricated threads.
VALUES
- 40 to 150
0.12
0.69
0.14
0.82
0.033
4 to 6
176
UNITS
A
°C
A
kA2s
kA2√s
V
mΩ
V
UNITS
°C
K/W
Nm
g
www.vishay.com
2
For technical questions, contact: ind-modules@vishay.com
Document Number: 94355
Revision: 29-Apr-08