English
Language : 

VS-MURB1020CTPBF Datasheet, PDF (1/9 Pages) Vishay Siliconix – Ultrafast Rectifier, 2 x 5 A FRED Pt®
VS-MURB1020CTPbF, VS-MURB1020CT-1PbF
Vishay High Power Products
Ultrafast Rectifier, 2 x 5 A FRED Pt®
VS-MURB1020CTPbF
VS-MURB1020CT-1PbF
Base
common
cathode
2
Base
common
cathode
2
1
2
3
Anode Common Anode
1 cathode 2
D2PAK
1
2
3
Anode Common Anode
1 cathode 2
TO-262
PRODUCT SUMMARY
trr
IF(AV)
VR
25 ns
2x5A
200 V
FEATURES
• Ultrafast recovery time
• Low forward voltage drop
• Low leakage current
• 175 °C operating junction temperature
• Meets MSL level 1, per J-STD-020, LF maximum
peak of 260 °C
• Halogen-free according to IEC 61249-2-21
definition
• Compliant to RoHS directive 2002/95/EC
• AEC-Q101 qualified
DESCRIPTION/APPLICATIONS
MUR.. series are the state of the art ultrafast recovery
rectifiers specifically designed with optimized performance
of forward voltage drop and ultrafast recovery time.
The planar structure and the platinum doped life time
control, guarantee the best overall performance,
ruggedness and reliability characteristics.
These devices are intended for use in the output rectification
stage of SMPS, UPS, dc-to-dc converters as well as
freewheeling diode in low voltage inverters and chopper
motor drives.
Their extremely optimized stored charge and low recovery
current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
ABSOLUTE MAXIMUM RATINGS
PARAMETER
Peak repetitive reverse voltage
Average rectified forward current
per leg
total device
Non-repetitive peak surge current per leg
Peak repetitive forward current per leg
Operating junction and storage temperatures
SYMBOL
VRRM
IF(AV)
IFSM
IFM
TJ, TStg
TEST CONDITIONS
Rated VR, TC = 149 °C
Rated VR, square wave, 20 kHz, TC = 149 °C
MAX.
200
5
10
50
10
- 65 to 175
UNITS
V
A
°C
ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
TEST CONDITIONS
Breakdown voltage,
blocking voltage
VBR,
VR
IR = 100 μA
IF = 5 A, TJ = 125 °C
Forward voltage
VF
IF = 10 A, TJ = 125 °C
IF = 10 A, TJ = 25 °C
Reverse leakage current
VR = VR rated
IR
TJ = 150 °C, VR = VR rated
Junction capacitance
CT
VR = 200 V
Series inductance
LS
Measured lead to lead 5 mm from package body
MIN.
200
-
-
-
-
-
-
-
TYP.
-
0.87
1.02
1.12
-
-
8
8.0
MAX. UNITS
-
0.99
V
1.20
1.25
10
μA
250
-
pF
-
nH
Document Number: 94518
Revision: 11-Mar-10
For technical questions, contact: diodestech@vishay.com
www.vishay.com