English
Language : 

APD-192G064-1 Datasheet, PDF (1/3 Pages) Vishay Siliconix – Plasma Panel Display Modules 192 x 64 Graphics Display with Drive Electronics TTL Level Data Interface and Integrated DC Converter
APD-192G064-1
Vishay Dale
Plasma Panel Display Modules
192 x 64 Graphics Display with Drive Electronics
TTL Level Data Interface and Integrated DC Converter
FEATURES
• TTL level video interface.
• On board DC converter.
• Slim profile.
• Large, bright characters and graphics.
• Highly visible for long distance viewing.
The APD-192G064-1 has been designed to offer high
brightness and superior viewing aesthetics in a package that
is very affordable. This display is ideal for low to medium
level information content messages and would be ideal for
applications such as arcade games, process control, POS
terminals, medical equipment, message centers and ATM
machines.
STANDARD ELECTRICAL SPECIFICATIONS*
DESCRIPTION SYMBOL MIN. TYP. MAX. UNITS
DC converter input VDC
+ 10.0 + 24.0 + 28.0 VDC
DC converter
power @ + 12 V
Amps Screen Clear 50% Lit 100% Lit —
0.100
1.7
3.5
Logic 1 Input
Vih
2.0
—
— VDC
Logic 0 Input
Vil
—
—
0.8 VDC
*Recommended operating voltages. All maximums are absolute
maximum.
DIMENSIONS in inches [millimeters]
192 x 64 Full Field
Pixel Pitch: 0.080 [2.03]
Pixel Size: 0.050 [1.27]
17.055 [433.20]
6.975 ±
0.010
[177.17
± 0.254]
6.663
[169.24]
Center of Active Area
0.156
[3.96]
5.090
[129.29]
6.19
[157.23]
0.156
[3.96]
8.527 [216.59]
15.330 [389.38]
16.68 [423.67]
17.367 ± 0.010
[441.12 ± 0.254]
3.217 0.403
[81.71] [10.24]
0.840
[21.34]
0.447 ± 0.025
[11.35 ±
0.635]
Pin 1 of P1
10.135 [257.43] Ref.
11.86 [301.24]
Ref.
..............
Pin 1
of P2
1.10 [27.94]
Max.
Component
Height
ELECTRICAL SPECIFICATIONS
Voltages Required: VDC: + 12 to + 24 VDC.
Power Required: Typical = 12 watts.
Maximum = 55 watts.
OPTICAL SPECIFICATIONS
Viewing Area: 15.33" [389.38] W x 5.09" [129.29] H.
Pixel Pitch: 0.080" [2.032].
Pixel Size: 0.050" [1.27].
Color: Neon orange.
Character Array: 8 x 8: 24 x 16. 6 x 8: 32 x 16.
Character Size: 0.48" [12.19] W x 0.64" [16.26] H .
Luminance: 50 foot lamberts minimum.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature: 0°C to + 70°C.
Storage Temperature: - 40°C to + 85°C.
Relative Operating Humidity: To 95% non-condensing.
Mechanical Shock: 30 G.
Vibration: 3 G.
Operating Altitude: 10,000 feet.
GENERAL DESCRIPTION
The APD-192G064-1 DC Plasma display offers viewing
qualities designers seek such as high contrast, viewing
angle of 150° minimum, and long distance readability.
It is bright (50 foot lamberts minimum) with characters and
graphics figures presented in a pleasing neon orange color
against a black background. Plasma is much more readable
and eye-pleasing than liquid crystal or vacuum fluorescent
displays and is filterable to red, amber, or neutral density.
These plasma display panels are driven in a standard
row - column refresh method much like a CRT display. The
designer need only supply TTL level signals for SERIAL
DATA, DOT CLOCK, COLUMN LATCH, ROW DATA, ROW
CLOCK and DISPLAY ENABLE. The SERIAL DATA is
entered with the DOT CLOCK up to frequencies as high as
8mHz. After a row of 192 pixels is clocked in, the COLUMN
LATCH signal is toggled and the data is latched. At the time
the data is latched, the display is briefly disabled using the
DISPLAY ENABLE signal, then the row pointer is advanced
with the ROW CLOCK signal. Once each frame the ROW
DATA must be asserted to synchronize the column serial
data with the beginning row. The recommended scanning
frequency is approximately 70 Hz but may be as high as 200
Hz. The high clock rate on the data clock allows for rapid
refresh and maximum access time to the refresh ram.
www.vishay.com
2
Document Number: 37013
Revision 05-Dec-00