English
Language : 

1840310-4 Datasheet, PDF (1/4 Pages) Vishay Siliconix – AC and Pulse Metallized Polypropylene Film Capacitors MKP Radial Potted Type
MKP 1840
Vishay Roederstein
AC and Pulse Metallized Polypropylene Film Capacitors
MKP Radial Potted Type
Dimensions in millimeters
l
max.
w
max.
Marking
h
max.
0.6
Pitch
± 0.4
6-1
± 0.4
Ø 0.8
LEAD DIAMETER
dt (mm)
0.5
0.6
0.8
1.0
W
(mm)
-
-
< 16
≥ 16.5
PITCH
(mm)
5
7.5/10
15 to 37.5
15 to 37.5
MAIN APPLICATIONS
Pulse operations, deflection circuits in TV-sets
(S-correction), SMPS and thyristor circuits, storage, filter,
timing, sample and hold circuits.
DIELECTRIC
Polypropylene film
ELECTRODES
Metallized
COATING
Flame retardant plastic case (class UL 94 V0), epoxy resin
sealed.
CONSTRUCTION
Extended metallized film (refer to General Information)
LEADS
Tinned wire
IEC TEST CLASSIFICATION
55/100/56, according to IEC 60068
OPERATING TEMPERATURE RANGE
- 55 °C to + 100 °C
CAPACITANCE RANGE
4700 pF to 10 µF
FEATURES
• Compliant to RoHS Directive 2002/95/EC
CAPACITANCE TOLERANCES
± 20 % (M), ± 10 % (K), ± 5 % (J)
RATED VOLTAGES (UR)
100 VDC,160 VDC, 250 VDC, 400 VDC, 630 VDC
INSULATION RESISTANCE
Measured at 100 VDC after one minute
For C ≤ 0.33 µF:
25 000 MΩ (UR 100 VDC)
PERMISSIBLE AC VOLTAGES (RMS) UP TO 60 Hz
63 VAC, 100 VAC, 160 VAC, 220 VAC, 250 VAC
TEST VOLTAGE (ELECTRODE/ELECTRODE)
1.6 x UR for 2 s
TIME CONSTANT
Measured at 100 VDC after one minute
For C > 0.33 µF:
30 000 s minimum value
TEMPERATURE COEFFICIENT
- 250 x 10-6/°C (typical value)
CAPACITANCE DRIFT
Up to + 40 °C, < 0.5 % for a period of two years
DIELECTRIC ABSORPTION
0.05 % (typical value) according to IEC 60068-2-21
DERATING FOR DC AND AC CATEGORY
VOLTAGE UC
At + 85 °C: UC = 1.0 UR
At + 100 °C: UC = 0.7 UR
SELF INDUCTANCE
~ 6 nH measured with 2 mm long leads
PULL TEST ON LEADS
≥ 30 N in direction of leads according to IEC 60068-2-21
For further details, please refer to the general information
available at www.vishay.com/doc?26033.
MAXIMUM PULSE RISE TIME
PCM
(mm)
5
100 VDC
390
Maximum Pulse Rise Time dV/dt [V/µs]
160 VDC
250 VDC
400 VDC
-
-
-
7.5
-
240
300
-
10
-
175
20
-
15
-
100
125
200
22.5
-
60
75
120
27.5
-
45
60
95
37.5
-
30
40
65
Note
• If the maximum pulse voltage is less than the rated voltage higher dV/dt values can be permitted.
630 VDC
-
-
510
280
160
120
85
Document Number: 26061
Revision: 30-Nov-10
For technical questions, contact: dc-film@vishay.com
www.vishay.com
147