Figure 9
Typical switching times as a
function of collector current
t = f(IC)
1,00
tdoff
0,10
tf
0,01
tdon
tr
V23990-P541-*3*-PM
Output Inverter
Output inverter IGBT
Figure 10
Typical switching times as a
function of gate resistor
t = f(RG)
1,00
tdoff
0,10
tf
0,01
Output inverter IGBT
tdon
tr
0,00
0
2
4
6
With an inductive load at
Tj =
125
°C
VCE =
300
V
VGE =
15
V
Rgon =
32
Ω
Rgoff =
16
Ω
Figure 11
Typical reverse recovery time as a
function of collector current
trr = f(IC)
0,25
0,20
Tj = Tjmax -25°C
0,15
0,10
Tj = 25°C
0,05
0,00
0
2
4
6
At
Tj =
VCE =
VGE =
Rgon =
25/125 °C
300
V
15
V
32
Ω
0,00
8
10 I C (A) 12
0
50
100
150
200
250 R G ( Ω ) 300
With an inductive load at
Tj =
125
°C
VCE =
300
V
VGE =
15
V
IC =
6
A
Output inverter FWD
trr
trr
Figure 12
Typical reverse recovery time as a
function of IGBT turn on gate resistor
trr = f(Rgon)
0,4
0,3
Tj = Tjmax -25°C
0,2
Tj = 25°C
0,1
Output inverter FWD
trr
trr
0,0
8
10 I C (A) 12
0
50
100
150
200
250 R g on ( Ω ) 300
At
Tj =
VR =
IF =
VGE =
25/125 °C
300
V
6
A
15
V
copyright Vincotech
7
Revision: 4