English
Language : 

10-RZ126PA035SC-M620F41 Datasheet, PDF (7/16 Pages) Vincotech – Clip-in PCB mounting (optional)
10-RZ126PA035SC-M620F41
10-R0126PA035SC-M620F40
Output Inverter
Figure 13
Typical reverse recovery charge as a
function of collector current
Qrr = f(IC)
8
6
Tj = 150°C
4
2
Tj = 25°C
Output inverter FWD
Qrr
Qrr
0
0
At
15
30
45
60
I C (A) 75
At
Tj =
VCE =
VGE =
Rgon =
25/150 °C
600
V
±15
V
16
Ω
Figure 14
Typical reverse recovery charge as a
function of IGBT turn on gate resistor
Qrr = f(Rgon)
6
Tj = 150°C
5
Output inverter FWD
Qrr
4
3
Tj = 25°C
Qrr
2
1
0
0
15
30
45
60
R g on ( Ω) 75
At
Tj =
VR =
IF =
VGE =
25/150 °C
600
V
35
A
±15
V
Figure 15
Typical reverse recovery current as a
function of collector current
IRRM = f(IC)
25
Tj = 150°C
20
15
Tj = 25°C
10
Output inverter FWD
IRRM
IRRM
5
0
0
15
30
45
60
I C (A)
75
At
Tj =
VCE =
VGE =
Rgon =
25/150 °C
600
V
±15
V
16
Ω
Figure 16
Typical reverse recovery current as a
function of IGBT turn on gate resistor
IRRM = f(Rgon)
35
30
25
20
Tj=150°C
15
Tj=25°C
10
5
0
0
15
30
45
At
Tj =
VR =
IF =
VGE =
25/150 °C
600
V
35
A
±15
V
Output inverter FWD
IRRM
IRRM
60 R gon ( Ω ) 75
Copyright by Vincotech
7
Revision: 2