flow NPC 1
NPC Application
650 V / 150 A
figure 23.
per MODULE
Typical available output current as a function of
heat sink temperature
I out=f(T h)
250
2kHz
200
150
figure 24.
Typical available output current
as a function of phase displacement
I out=f(φ )
250
per MODULE
Ts = 50 °C
200
Ts = 100 °C
150
100
100
128kHz
50
50
0
60
70
80
90
T h ( o C) 100
Conditions:
T j= T jmax-25 °C
DC-link= 700 V
φ= 0 °
parameter:
Switching freq.
f sw from
2
in steps of factor 2
kHz to
128 kHz
figure 25.
per MODULE
Typical available output current as a function of
switching frequency
I out=f(f sw)
250
Ts = 50 °C
200
150
Ts = 100 °C
100
50
0
1
10
100
f sw (kHz)
Conditions:
T j= T jmax-25 °C
φ=
0°
DC-link= 700 V
parameter:
Heatsink temp.
T s from 50 °C to
100
in 10 °C
steps
0
0
30
60
90
120
150
180
φ
Conditions:
T j= T jmax-25 °C
DC-link= 700 V
f sw=
16
kHz
parameter:
Heatsink temp.
T s from 50 °C to
in 10 °C
100
steps
figure 26.
per MODULE
Typical available 50Hz output current as a function of
f sw and phase displacement
I out=f(f sw,φ )
180
I out (A)
165
φ
150
200-230
135
170-200
120
105
140-170
90
110-140
75
60
80-110
45
50-80
30
15
0
2 4 8 16 32 64 128
f sw (kHz)
Conditions:
T j= T jmax-25 °C
DC-link= 700 V
T s= 80 °C