English
Language : 

10-FZ06NIA050SA-P925F33 Datasheet, PDF (7/9 Pages) Vincotech – flowNPC0
10-FZ06NIA050SA-P925F33
preliminary datasheet
flowNPC0
NPC Application
600V/50A
Figure 23.
Typical available output current as a function of
heat sink temperature
Iout=f(Th)
70
60
50
40
per MODULE
2kHz
Figure 24.
Typical available output current
as a function of phase displacement
Iout=f(φ)
70
Th=50°C
60
50
Th=100°C
40
per MODULE
30
30
20
20
10
128kHz
0
60
65
70
75
80
85
90
95
100
Th (oC)
Conditions:
Tj= Tjmax-25 °C
DC link= 700 V
φ= 0 °
parameter:
Switching freq.
fsw from
2
kHz to
in steps of factor 2
128 kHz
Figure 25.
Typical available output current as a function of
switching frequency
Iout=f(fsw)
70
Th=50°C
60
per MODULE
50
40
Th=100°C
30
20
10
0
1
10
Conditions:
Tj= Tjmax-25 °C
φ=
DC link= 700 V
parameter:
Heatsink temp.
Th from 50 °C to
100
in 10 °C
steps
100
fsw (kHz)
0°
10
0
0
15 30 45 60 75 90 105 120 135 150 165 180
φ
Conditions:
parameter:
Tj= Tjmax-25 °C
DC link= 700 V
fsw=
20
kHz
Heatsink temp.
Th from 50 °C to
in 10 °C
100
steps
Figure 26.
per MODULE
Typical available 50Hz output current as a function of
fsw and phase displacement
Iout=f(fsw,φ)
180
φ
165
Iout (A)
150
55-60
135
50-55
120
45-50
105
40-45
90
35-40
30-35
75
25-30
60
20-25
45
15-20
30
10-15
15
0
2 4 8 16 32 64 128
fsw (kHz)
Conditions:
Tj= Tjmax-25 °C
DC link= 700 V
Th=
80
°C
copyright by Vincotech
7
Revision: 1