English
Language : 

V23990-P634-A-P1-14 Datasheet, PDF (6/18 Pages) Vincotech – IGBT FRED
flow 90PIM 1 600V/20A
V23990-P634-A-PM
preliminary data sheet
V23990-P634-A-02-14
Output inverter
Figure 5.
Typical switching energy losses
as a function of collector current
Output inverter IGBT
E = f (Ic)
1,6
1,4
Eon
1,2
1
0,8
Eoff
0,6
0,4
Erec
0,2
0
0
8
16
24
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Rgon= 16 ȍ
Rgoff= 8 ȍ
32 I C (A) 40
Figure 6.
Typical switching energy losses
as a function of gate resistor
Output inverter IGBT
E = f (RG)
1,6
1,4
Eon
1,2
1
0,8
Eoff
0,6
0,4
0,2
0
0
30
60
90
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Ic = 20 A
Erec
120 R G ( : ) 150
Figure 7.
Typical switching times as a
function of collector current
Output inverter IGBT
t = f (Ic)
1
0,1
0,01
tr
tdoff
tf
tdon
0,001
0
8
16
24
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Rgon= 16 ȍ
Rgoff= 8 ȍ
32
IC (A) 40
Figure 8.
Typical switching times as a
function of gate resistor
Output inverter IGBT
t = f (RG)
1
tdoff
0,1
tf
tdon
tr
0,01
0,001
0
30
60
90
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Ic = 20 A
120 R G ( : ) 150
coCpyorigphyt bryigThyctobEylecVtroinniccsotech
Finsinger Feld 1, D-85521 Ottobrunn
Revision:1