English
Language : 

V23990-P630-A40-PM Datasheet, PDF (6/23 Pages) Vincotech – Clip-in PCB mounting
V23990-P630-A40-PM
Output Inverter
Figure 5
Typical switching energy losses
as a function of collector current
E = f(IC)
5
4
3
2
1
0
0
5
10
15
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
Rgoff =
25/150 °C
600
V
±15
V
32
Ω
32
Ω
Output inverter IGBT
Eon High T
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
5
4
3
Eon Low T
Eoff High T
2
Eoff Low T
1
0
20
25 I C (A) 30
0
30
60
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/150 °C
600
V
±15
V
15
A
Output inverter IGBT
Eon High T
Eon Low T
Eoff High T
Eoff Low T
90
120
R G ( Ω ) 150
Figure 7
Typical reverse recovery energy loss
as a function of collector current
Erec = f(IC)
1,5
1,2
Output inverter FWD
Erec
Tj = Tjmax -25°C
0,9
Erec
0,6
Tj = 25°C
0,3
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
1,5
Tj = Tjmax -25°C
1,2
0,9
Tj = 25°C
0,6
0,3
Output inverter FWD
Erec
Erec
0
0
0
5
10
15
20
25 I C (A) 30
0
30
60
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
Rgon =
32
Ω
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
IC =
15
A
90
120 R G ( Ω ) 150
copyright Vincotech
6
Revision: 2