English
Language : 

10-FZ06NRA060FU-P967F08 Datasheet, PDF (6/27 Pages) Vincotech – Neutral point clamped inverter
10-FZ06NRA060FU-P967F08
10-PZ06NRA060FU-P967F08Y
datasheet
Buck
Figure 5
Typical switching energy losses
as a function of collector current
E = f(IC)
0,8
0,6
0,4
0,2
0
0
10
20
30
40
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
Rgoff =
25/125 °C
350
V
±15
V
4
Ω
4
Ω
Figure 7
Typical reverse recovery energy loss
as a function of collector current
Erec = f(Ic)
0,20
0,15
0,10
0,05
0,00
0
10
20
30
40
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
25/125 °C
350
V
±15
V
4
Ω
IGBT
Eon High T
Eoff High T
Eon Low T
Eoff Low T
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
0,5
0,4
0,3
0,2
0,1
0,0
50
60
I C (A)
0
4
8
12
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/125 °C
350
V
±15
V
30
A
FWD
Erec High T
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
0,10
0,08
0,06
0,04
Erec Low T
0,02
0,00
50
I C (A) 60
0
4
8
12
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/125 °C
350
V
±15
V
30
A
IGBT
Eon High T
Eoff High T
Eon Low T
Eoff Low T
16
R G ( Ω) 20
FWD
Erec High T
Erec Low T
16
R G ( Ω) 20
copyright Vincotech
6