English
Language : 

V23990-P824-F-P2-14 Datasheet, PDF (5/16 Pages) Vincotech – Trench Fieldstop IGBT3 Technology
Output Inverter
V23990-P824-F-PM
preliminary datasheet
Figure 5
Typical switching energy losses
as a function of collector current
E = f(Ic)
5
4
3
2
1
Output inverter IGBT
Eoff
Eoff
Eon
Eon:
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
5
4
3
2
1
Output inverter IGBT
Eon
Eoff
Eon
Eoff
0
0
30
60
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
Rgoff =
25/150 °C
300
V
±15
V
4
Ω
4
Ω
0
90
120
I C (A) 150
0
4
8
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/150 °C
300
V
±15
V
75
A
12
16 R G ( Ω ) 20
Figure 7
Typical reverse recovery energy loss
as a function of collector current
Erec = f(Ic)
2,5
2
Output inverter IGBT
Erec
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
2,5
2
Output inverter IGBT
1,5
1,5
Erec
Erec
1
1
Erec
0,5
0,5
0
0
30
60
90
120 I C (A) 150
0
0
4
8
12
16 R G ( Ω ) 20
With an inductive load at
Tj =
25/150 °C
VCE =
300
V
VGE =
±15
V
Rgon =
4
Ω
With an inductive load at
Tj =
25/150 °C
VCE =
300
V
VGE =
±15
V
IC =
75
A
copyright by Vincotech
5
Revision: 2