English
Language : 

V23990-P729-F44-D1-14 Datasheet, PDF (5/12 Pages) Vincotech – Maximum Ratings / Höchstzulässige Werte
V23990-P729-F44-PM
fastPACK0 H 2nd gen
Output inverter
Figure 5. Typical switching energy losses
as a function of collector current
Output inverter IGBT
E = f (Ic)
3,5
3
Eon
2,5
Eoff
2
Erec
1,5
1
0,5
0
0
10
20
30
inductive load, Tj = 125 °C
VCE = 600 V
VGE= ±15 V
Rgon= 16 ȍ
Rgoff= 16 ȍ
40 I C (A) 50
Figure 7.
Typical switching times as a
function of collector current
Output inverter IGBT
t = f (Ic)
1
tdon
0,1
tf
0,01
tdoff
tr
V23990-P729-F44
Figure 6.
3,5
3
Typical switching energy losses
as a function of gate resistor
Output inverter IGBT
E = f (RG)
Eon
2,5
Erec
2
1,5
Eoff
1
0,5
0
0
15
30
45
inductive load, Tj = 125 °C
VCE = 600 V
VGE= ±15 V
Ic = 25 A
60 R G ( : ) 75
Figure 8.
1
Typical switching times as a
function of gate resistor
Output inverter IGBT
t = f (RG)
tdoff
tdon
0,1
tf
tr
0,01
0,001
0
10
20
30
inductive load, Tj = 125 °C
VCE = 600 V
VGE= ±15 V
Rgon= 16 ȍ
Rgoff= 16 ȍ
40 IC (A) 50
0,001
0
15
30
45
inductive load, Tj = 125 °C
VCE = 600 V
VGE= ±15 V
Ic = 25 A
60 R G ( : ) 75
Copyright by Vincotech
5
Revision: 1