English
Language : 

V23990-P700-F44 Datasheet, PDF (5/17 Pages) Vincotech – Trench Fieldstop IGBT4 Technology
Figure 5
Typical switching energy losses
as a function of collector current
E = f(IC)
12
10
8
6
4
2
0
0
25
50
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
Rgoff =
25/150 °C
600
V
±15
V
8
Ω
8
Ω
Figure 7
Typical reverse recovery energy loss
as a function of collector current
Erec = f(IC)
5
4
3
Tj = Tjmax -25°C
2
1
Tj = 25°C
0
0
25
50
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
Rgon =
8
Ω
Output Inverter
V23990-P700-F44
preliminary datasheet
Output inverter IGBT
Eon High T
Eoff High T
Eon Low T
Eoff Low T
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
12
10
8
6
4
2
75
I C (A)
100
0
0
8
16
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/150 °C
600
V
±15
V
50
A
Output inverter IGBT
Eon High T
Eon Low T
Eoff High T
Eoff Low T
24
32
R G ( Ω ) 40
Output inverter FWD
Erec
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
5
Tj = Tjmax -25°C
4
3
Erec
Tj = 25°C
2
1
Output inverter FWD
Erec
Erec
0
75
I C (A)
100
0
8
16
24
32
R G ( Ω ) 40
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
IC =
50
A
copyright Vincotech
5
Revision: 1