English
Language : 

10-FZ122PA100SC-P999F08 Datasheet, PDF (5/15 Pages) Vincotech – Trench Fieldstop IGBT technology
Output Inverter
FZ12 / F0122PA100SC
preliminary datasheet
Figure 5
Typical switching energy losses
as a function of collector current
E = f(IC)
30
25
20
15
10
5
0
0
40
80
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
Rgoff =
25/150 °C
600
V
±15
V
4
Ω
4
Ω
Output inverter IGBT
Eon High T
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
30
25
20
Eon Low T
15
Eoff High T
10
Eoff Low T
5
0
120
160
I C (A) 200
0
4
8
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/150 °C
600
V
±15
V
100
A
Output inverter IGBT
Eon High T
Eon Low T
Eoff High T
Eoff Low T
12
16 R G ( Ω ) 20
Figure 7
Typical reverse recovery energy loss
as a function of collector current
Erec = f(IC)
10
8
Tj = Tjmax -25°C
6
4
2
Output inverter IGBT
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
10
Erec
8
6
Tj = 25°C
Erec
4
2
Tj = Tjmax -25°C
Tj = 25°C
Output inverter IGBT
Erec
Erec
0
0
0
40
80
120
160
I C (A) 200
0
4
8
12
16 R G ( Ω ) 20
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
Rgon =
4
Ω
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
IC =
100
A
Copyright by Vincotech
5
Revision: 1