English
Language : 

V23990-P840-X5X-P2-19 Datasheet, PDF (3/4 Pages) Vincotech – Output Inverter Application
V23990-P840-A58/A59/C58/C59-PM
preliminary datasheet
Output Inverter Application
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
12,0
2kHz
Inverter
10,0
8,0
6,0
16kHz
4,0
2,0
0,0
60
65
70
75
80
85
90
95
Th
( o C)
100
Tj =
125
°C
DC link = 600
V
Mi =
1
cosfi = 0,80
fsw from 2 kHz to 16 kHz in 2 steps
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
1,00 / 0,74
1
1123
2
1123
4
1123
8
1047
16
823
1,50 / 1,10
749
749
749
698
549
2,00 / 1,47
562
562
562
523
412
At
Tj =
125
°C
DC link = 600
V
Mi =
1
cosfi = 0,8
fsw from 1 kHz to 16 kHz in 2 steps
Th =
90
°C
Motor eff = 0,85
3,00 / 2,21
374
374
374
349
274
5,00 / 3,68
225
225
225
209
165
7,50 / 5,52
150
150
150
140
0
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
2kHz
99,0
Inverter
98,0
97,0
96,0
16kHz
95,0
94,0
0,0
2,0
4,0
6,0
8,0
10,0
12,0
14,0
16,0
Pout (kW)
Tj =
125
°C
DC link = 600
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in 2 steps
copyright Vincotech
3
Revision: 2