V23990-P823-F10-P2-19 Datasheet, PDF (3/4 Pages) Vincotech – Typical average static loss as a function of output current
flowPACK 1 3rd gen
Output Inverter Application
V23990-P823-F10-PM
preliminary datasheet
600V/50A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
20,0
Inverter
18,0
16,0
2kHz
14,0
12,0
10,0
16kHz
8,0
6,0
4,0
2,0
0,0
60
65
70
75
80
85
90
95
Th
( o C)
100
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi = 0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
002 / 001
1
1120
2
1101
4
1064
8
993
16
866
002 / 001
840
826
798
745
649
003 / 002
560
551
532
497
433
005 / 004
336
330
319
298
260
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi = 0,8
fsw from 1 kHz to 16kHz in steps of factor 2
Th =
90
°C
Motor eff = 0,85
008 / 006
224
220
213
199
173
010 / 007
168
165
160
149
130
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
99,0
2kHz
98,0
97,0
96,0
16kHz
95,0
94,0
93,0
92,0
91,0
90,0
0,0
5,0
10,0
15,0
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Inverter
20,0
25,0
Pout (kW)
copyright by Vincotech
3
Revision: 2