V23990-P820-F10-P2-19 Datasheet, PDF (3/4 Pages) Vincotech – Typical average static loss as a function of output current
flowPACK 1 3rd gen
Output Inverter Application
V23990-P820-F10-PM
preliminary datasheet
1200V/75A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
50,0
Inverter
45,0
40,0
2kHz
35,0
30,0
25,0
20,0
15,0
16kHz
10,0
5,0
0,0
60
65
70
75
80
85
90
95
Th
( o C)
100
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi = 0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
005 / 004
1
785
2
741
4
662
8
533
16
364
008 / 006
523
494
441
355
243
010 / 007
393
371
331
267
182
015 / 011
262
247
221
178
121
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi = 0,8
fsw from 1 kHz to 16kHz in steps of factor 2
Th =
90
°C
Motor eff = 0,85
020 / 015
196
185
165
133
0
025 / 018
157
148
132
0
0
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
99,0
2kHz
98,0
97,0
96,0
95,0
16kHz
94,0
93,0
92,0
91,0
90,0
0,0
10,0
20,0
30,0
40,0
50,0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Inverter
60,0
70,0
Pout (kW)
copyright by Vincotech
3
Revision: 2