English
Language : 

V23990-P768-A60-D2-19 Datasheet, PDF (3/3 Pages) Vincotech – flowPIM 2
flowPIM 2
Output Inverter Application
V23990-P768-A60-PM
datasheet
1200 V / 50 A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
35,0
30,0
Inverter
2kHz
25,0
20,0
16kHz
15,0
10,0
5,0
0,0
60
65
70
75
80
85
90
95Th ( o C) 100
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
100 Motor nominal power (HP/kW)
7,50 / 5,52 10,00 / 7,36 15,00 / 11,03
1
499
374
250
2
499
374
250
4
499
374
250
8
480
360
240
16
368
276
184
20,00 / 14,71
187
187
187
180
138
25,00 / 18,39
150
150
150
144
110
30,00 / 22,07
125
125
125
120
0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
99,0
2kHz
Inverter
98,0
97,0
96,0
16kHz
95,0
94,0
93,0
92,0
91,0
90,0
0,0
5,0
10,0
15,0
20,0
25,0
30,0
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
35,0 P4o0u,t0(kW) 45,0
copyright Vincotech
3
23 Dec 2014 / Revision 2