V23990-P760-A-P1-19 Datasheet, PDF (3/3 Pages) Vincotech – Output Inverter Application
flowPIM 2 3rd
Output Inverter Application
V23990-P760-A-PM
prel datasheet
1200V/100A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
60,0
2kHz
50,0
Inverter
40,0
30,0
16kHz
20,0
10,0
0,0
60
65
70
75
80
85
90
95
Th
( o C)
100
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi = 0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
450
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
15,00 / 11,03 20,00 / 14,71 25,00 / 18,39 30,00 / 22,07 40,00 / 29,42 50,00 / 36,78
1
424
318
254
212
159
127
2
424
318
254
212
159
127
4
409
307
245
204
153
123
8
353
265
212
176
132
0
16
266
200
160
133
0
0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi = 0,8
fsw from 1 kHz to 16 kHz in 2 steps
Th =
80
°C
Motor eff = 0,85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
99,0
2kHz
Inverter
98,0
97,0
16kHz
96,0
95,0
94,0
0,0
10,0
20,0
30,0
40,0
50,0
60,0
70,0
80,0
Pout (kW)
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
copyright Vincotech
3
Revision: 1