English
Language : 

V23990-P760-A-D2-19 Datasheet, PDF (3/3 Pages) Vincotech – flow PIM 2 3rd
flowPIM 2 3rd
V23990-P760-A-PM
datasheet
Output Inverter Application
1200 V / 100 A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
60
2kHz
Inverter
50
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
99,0
2kHz
Inverter
40
98,0
30
97,0
16kHz
16kHz
20
96,0
10
95,0
0
60
65
70
75
80
85
90
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
95
Th
( o C) 100
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
450
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
15,00 / 11,03 20,00 / 14,71 25,00 / 18,39
1
424
318
254
2
424
318
254
4
409
307
245
8
353
265
212
16
266
200
160
30,00 / 22,07
212
212
204
176
133
40,00 / 29,42
159
159
153
132
0
50,00 / 36,78
127
127
123
0
0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,8
fsw from 1 kHz to 16 kHz in 2 steps
Th =
80
°C
Motor eff = 0,85
94,0
0
10
20
30
40
50
60
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
70
80
Pout (kW)
copyright Vincotech
3